€0.67
Price | Disc. | Quantity | Validity |
---|---|---|---|
€0.67 | 0 % | from 1 piece |
Available
High-quality TV/satellite coax (A-class, 16.65dB/100m at 860 MHz) in PE sheath, gel-filled. For outdoor applications.
Details
The high quality coaxial cable Triset-113 PE E1017_1 is used in individual and community antenna installations, SMATV systems etc., for distribution of DVB-T, FM/DAB, DVB-S/S2 broadcasts (also in multiswitch systems). Thanks to PE coating, the gel-filled cable can be installed outdoors, e.g. for connecting antennas placed on roofs etc.
Cable structure.
Key features
- complies with A-class requirements
- passed IEC 68-2-3 Steady State Damp Heat test
- 1.13 mm copper core
- low loss
- perfect matching,
- high screening efficiency - A+ class in the vast majority of the transmission range
- 81% braid coverage
- 5-year warranty
TRISET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
TRISET-113 cables comply with the EN50117 standard and A-class requirements in the whole 5...3000 MHz transmission frequency range.
RoHS compliance declaration.
Triset-113 PE E1017_1 cable has a braid coverage of 81%, which is the basis for high screening efficiency.
The high-quality, double shielded coaxial cable of RG6 category has the inner conductor made of copper wire with a diameter of 1.13 mm, which ensures low loss and durability. The copper wire core does not corrode and the cable is not stiff.
Thanks to high quality and excellent parameters, the cable enjoys great popularity among many installers. An optimum flexibility of the jacket allows for easy installation of the cable in cable ducts and installation boxes.
The cable is manufactured under strict technological discipline, with tight tolerances.
In order to secure the minimum bend radius, flush mounted installations should be done with the use of protective tubes.
Screening efficiency of TRISET-113 cable in the 30-3000 MHz range
and the requirements for A class
Transfer impedance of TRISET-113 cable in 5-30 MHz range
and the requirements for A class
Insertion loss in the 5-2400 MHz frequency range
Return loss in the 5-2400 MHz frequency range
Signal propagation velocity in the 5-2400 MHz frequency range
The increase of attenuation after the accelerated aging test (IEC68-2-3) is below 5%
Coaxial cables undergo a natural aging process which results in increasing attenuation. The quality of a cable in the process of accelerated aging is tested according to IEC68-2-3 standard. The Triset cable passed the test and its quality is guaranteed by a 5-year warranty.
Specifications
Name | TRISET 113 PE | ||
Code | E1017 | ||
tolerance | |||
Copper core | |||
Diameter | mm | 1,13 | ± 0,03 |
Physically foamed dielectric | |||
Thickness | mm | 1,83 | ± 0,05 |
Diameter | mm | 4,80 | ± 0,1 |
Ovality (non-circularity) | ± 2% | ||
Al/PET/Al foil 30/12/30 µm adhered to the dielectric | |||
Width | mm | 18 | ± 0,3 |
Overlap | mm | >3 | ± 0,5 |
Total thickness | µm | 75 | ± 3 |
Braid | |||
Material | Aluminum | ||
Wire diameter | mm | 0,12 | ± 0,01 |
Number of wires | pc | 24 x 6 | |
Winding angle | degree | 19,34 | |
Braid coverage | % | 81 | |
Jacket | |||
Material | PE | ||
Thickness | mm | 0,8 | ± 0,1 |
Diameter | mm | 6,8 | +0,20/-0,05 |
Color | Black | ||
Electrical parameters | |||
Resistance (20°C) | Ω/km | 16,85 | ± 0,5 |
Capacitance | pF/m | 52 | ± 1,5 |
Dielectric resistance | MΩ/km | 2000 | ± 3% |
Impedance | Ω | 75 | ± 3 |
Wave reduction factor | % | 84 | ± 1 |
Mechanical parameters | |||
Operating temperature range | °C | -30...+70 | |
Installation temperature range | °C | -5...+40 | |
Minimum bending radius | mm | 35 (single) 70 (repeated) |
According to EN50117 norm, there are the next classes of coaxial cables, depending on screening efficiency: C, B, A, A+, A++.
Taking into consideration cables for antenna systems, Triset 113 has the highest screening efficiency, between A and A+.
Classes of screening efficiency
Class\freq. range | 5-30 MHz [mΩ/m] | 30-1000 MHz [dB] | 1-2 GHz [dB] | 2-3 GHz [dB] |
C | 50 | 75 | 65 | 55 |
B | 15 | 75 | 65 | 55 |
A | 5 | 85 | 75 | 65 |
A+ | 2.5 | 95 | 85 | 75 |
A++ | 0.9 | 105 | 95 | 85 |
Price for 1m
Specifications
Product type | Coaxial cable | ||
type | TRISET 113 | ||
Brand | TRISET | ||
Cable length | m | per meter | |
Applications | Outdoor | ||
Cable class | RG-6 | ||
CPR class | FCA | ||
Gel-filled cable | Yes | ||
Physical properties | |||
Impedance | Ohm | 75 | |
Screening efficiency class | A | ||
Transfer impedance TI | mΩ/m | <5 | |
Conductor | Material | Coper | |
Diameter | mm | 1,13 | |
Dielectric | foaming | Physical | |
Diameter | mm | 4,8 | |
shield | |||
No. of plies | 2 | ||
First foil | bonded to dielectric | Yes | |
Material | Al/PET/Al | ||
Dimensions | μm | 30/12/30 | |
total thickness | μm | 75 | |
Braid | Material | Aluminium | |
wire diameter | mm | 0,12 | |
no. of wires | pcs. | 24 × 6 | |
winding angle | degree | 19,34 | |
braid coverage | % | 81 | |
sheath | Material | PE | |
thickness | mm | 0,8 | |
Diameter | mm | 6,8 | |
Color | Black | ||
Electrical parameters | |||
Resistance at 20°C | Ω/km | 16,85 | |
capacity | pF/m | 52 | |
Wave reduction factor | % | 84 | |
Mechanical properties | |||
Operating temperature | °C | -30...+70 | |
Installation temperature | °C | -5...+40 | |
Minimum bending radius | mm | 35 (single) 70 (repeated) |