Galvanic Isolator: Signal (5-2400 MHz)
Code: R48605
Price
Disc.
Quantity
3.53 EUR
0 %
In bigger installations, the differences of potentials between individual parts of the antenna/cable networks may cause overvoltages and surge currents effecting in sparks when connecting the equipment (and even light electric shocks). It may also be the reason of unexpected damages of the equipment like amplifiers or even receivers. The solution to the problem is use of galvanic isolators.
The example of such devices is Signal unit. It ensures full galvanic isolation, i.e. both signal and shielding paths are completely separated from each side. Small size and low attenuation within all 5-1000 MHz range (not exceeding 1.5 dB) make it a very useful item protecting against potential risks. The galvanic isolator should be used at the input of a building network, as well as at the points of distributing the signal to individual staircase installations.
Specifications
| Name | Signal 5-2400 MHz |
| Code | R48605 |
| Frequency range | 5-1000 MHz |
| Attenuation: | |
| 5-550 MHz | <1 dB |
| 550-1000 MHz | <1.5 dB |
| Breakdown voltage 3000V for 1 minute test with current leak < 0.7 mA | |

In practice, such isolators should be used at the output of each building amplifier. Another application is to isolate the chassis of PC employing TV-tuner from the zero voltage rail of the cable system. This way, a difference of potentials does not harm signal quality, as well as modern sensitive cut-outs will not switch off the power network.

Characteristics of the device: BLUE - attenuation, RED - impedance matching

Example of application - isolation in each staircase