Amplifiers
Building
House/Building Amplifier DA-713 (Sat/TV/Return-ALCAD 904 series)
Specifications
| Code | R904025 | |
| Name | DA-713 | |
| Frequency range | Band | RETURN | TV | SAT |
| MHz | 5-30 | 47-862 | 930-2150 | |
| Gain | dB | 6 + / -0.5 | 34 + / -1 | 41 + / -2.5 |
| Gain adjustment | dB | - | 20 | 15 |
| Adjustable equalization range, constant | dB | 3.5 | - | 7 |
| Adjustable equalization range | dB | - | 16 |10 |
| Test output | dB | 30 +-0.5 | 30 +-0.2 |
| Output level | dBuV | 107 DIN 45004B / 104 (IMD3-60dB) | 120 DIN 45004B / 117 IMD3-60dB | 120 / 120 IMD3-35dB |
| dBuV | 90 (IMD2-60dB) | 110 (IMD2-60dB) | 110 (IMD2-35dB) | |
| dBuV | - | 105 CTB / 105 CSO/ 104 XMOD | - | |
| Reflected signal suppression | dB | >=14 | >=10 | >= 9 |
| Chrominance - luminance delay | ns | 80 |
| Group delay | ns | < 40 |
| Noise figure | dB | (XX) |
| Noise figure | dB | =< 7 | =< 10 |
| AC safety-catch | V | 250 |
| A | 5 | |
| AC input voltage | V | 230 +-15%, 50 / 60 Hz |
| Power consumption | VA | 12 |
| Working temperature | oC | -20...+65 |
| Case protection index | IP50D | |
| Gross weight | kg | 1,8 |
Output level reduction (according to DIN 45004B)
channel number | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| output level [dBuV] | 115 | 113 | 111 | 110 | 110 | 109 | 109 | 108 | 108 | 107 | 107 |
SECTION LIBRARY
LIBRARY NEW TITLES
TO KNOW MORE
Router connects two or more logical subnets, e.g. external network with Internet access (WAN) with local network (LAN), making a bridge for information exchange. Without... more »