Support
Details
The operating frequency range is 5-1000 MHz. The tap is equipped with F connectors and cast aluminum housing. The product ensures good quality and suitability for professional use. Continuous quality control guarantees repeatability of parameters.
The family of FAC taps contains wide range of devices with various number of outputs and different attenuation, which allows for effective distribution of antenna signals from high-output amplifiers, with the aim that the output level in any subscriber's outlet will be within the accepted 47-74 dBuV margin.
The family of FAC taps contains wide range of devices with various number of outputs and different attenuation, which allows for effective distribution of antenna signals from high-output amplifiers, with the aim that the output level in any subscriber's outlet will be within the accepted 47-74 dBuV margin.
Specifications
Name | FAC-2-10dB | ||
Code | R602210 | ||
Frequency range [MHz] | 5-40 | 40-470 | 470-1000 |
Tap loss [dB] | 10 +/-1 | 10 +/-1 | 10 +/-1 |
Insertion loss [dB] | 3.2 | 3.2 | 3.2 |
Screening efficiency [dB] | > 75 | > 75 | > 65 |
Return loss [dB] | > 16 | > 16 | > 16 |
Loss and return loss diagram for input - tap output (BLUE: attenuation, RED: return loss)
Loss and return loss diagram for input - output (BLUE: attenuation, RED: return loss)
Specifications
Product type | Tap | ||
Name | FAC-2-10 | ||
Applications | Terrestrial TV | ||
No. of outputs | pcs. | 2 | |
Number of pass-through outputs | pcs. | 1 | |
Operating band | MHz | 5 – 1000 | |
Branch attenuation | dB | 10 | |
Throughput attenuation | dB | 3,2 | |
DC pass-through | No |