UC300 26 Li-2YY 4x2x0.48L (AWG 26) 100W - SO/IEC 11801 CAT-5e UTP
Application according to standards: IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; IEEE 802.5 16 MB; ISDN; FDDI; ATM fire proof up to IEC 60332-1.
Structure: Copper wire diam. 0.48 mm (AWG26). Insulation: polyethylene (outer diam. 0.9 mm). Sheath: PVC.
Mechanical characteristics: Minimum bending radius: 40 mm; temperature range (after installation): -20 to + 60 deg(C), (when installing): 0 to + 50 deg(C).
Electrical characteristics (20 deg C): Resistance of each wire: <260 ohm/km; wire resistance unbalance of each pair: <3%; insulation resistance of each wire (500 V): > 2000 Mohm/km.
Effective capacitance of each pair (nominal value at 800 Hz): 48 nF/km; wave impedance (1-100 MHz): 100 +/-15 [ohm]; wave reduction factor: 67%.
Transmission characteristics
f. MHz | Wave | NEXT | PS- NEXT | ELFEXT | PS-ELFEXT | Attenuation | ||||
1 | 0.3 | 65 | 71 | 62 | 68 | 64 | 68 | 61 | 65 | 20 |
4 | 0.6 | 56 | 62 | 53 | 59 | 52 | 56 | 49 | 53 | 23 |
10 | 0.9 | 50 | 56 | 47 | 53 | 44 | 48 | 41 | 45 | 25 |
16 | 1.1 | 47 | 53 | 44 | 50 | 40 | 44 | 37 | 41 | 25 |
20 | 1.3 | 46 | 51 | 43 | 48 | 38 | 42 | 35 | 39 | 25 |
31.2 | 1.6 | 43 | 49 | 40 | 46 | 34 | 38 | 31 | 35 | 24 |
62.5 | 2.4 | 38 | 44 | 35 | 41 | 28 | 32 | 25 | 29 | 22 |
100 | 3.0 | 35 | 41 | 32 | 38 | 24 | 28 | 21 | 25 | 20 |
125 | 3.3 | 40 | 37 | 26 | 23 | 19 | ||||
155.5 | 3.6 | 38 | 35 | 24 | 21 | |||||
175 | 3.9 | 37 | 34 | 23 | 20 | |||||
200 | 4.1 | 36 | 33 | 22 | 19 | |||||
250 | 4.4 | 35 | 32 | 20 | 17 | |||||
300 | 4.8 | 34 | 31 | 16 | 13 |