Practical implementation of a home junction box.
| Price | Disc. | Quantity | Validity |
|---|---|---|---|
| €118.05 | 0 % | from 1 piece |
• Category 5e
• Application: indoor
• PVC sheath
• Core diameter 0.5 mm (24 AWG)
• Carton 305 m
Details
- top-quality materials, perfect workmanship confirmed by a 15 year guarantee
- parameters significantly exceeding requirements of category 5+
- pre-production quality control of raw materials and post-production quality control of the finished product
- metre marker
- single stranded copper conductors with a diameter of Ø 0.50 mm (24 according to AWG)
- conductor insulation made of PE uniform insulating polyethylene, mass-coloured, conductor diameter: Ø 0.88 mm, conductor insulation colours: white/green, white/orange, white/brown, white/blue
- insulated conductors twisted in pairs, pair diameter Ø 1.8 mm
- insulated conductors twisted into a centre, diameter of the centre ~ Ø 4,0 mm
- cable sheath made of PVC polyvinyl chloride, RAL 7032 grey colour, outer diameter Ø 5,0 mm
- imprinting error max. 0.5%
IEC 61156-6 (2000), ISO/IEC 11801 (2000), ANSI/TIA/EIA-568-A (1995), EN 50173 (1999), yd/t1019-2001 standards.
- Pair resistance and resistance asymmetry testing.
| Cable | Pair | Wire | Wire resistance [Ω/km] | Resistance asymmetry [%] |
| UTP cat. 5e | 1 | a | 92,726 | 0,35 |
| b | 93,054 | |||
| 2 | a | 94,662 | 0,34 | |
| b | 94,982 | |||
| 3 | a | 96,228 | 0,55 | |
| b | 96,755 | |||
| 4 | a | 96,107 | 0,39 | |
| b | 95,733 | |||
| Required | - | - | <150 | ≤3,0 |
- Effective capacitance and capacitance asymmetry testing.
| Cable | Pair | Effective capacitance [nF/km] | Capacitance asymmetry [pF/km] |
| UTP cat. 5e | 1 | 47,35 | 77 |
| 2 | 44,87 | 132 | |
| 3 | 45,71 | 36 | |
| 4 | 46,70 | 5 | |
| Required | - | - | ≤1600 |
- Insulation testing.
| Cable | Pair | Wire | Insulation resistance [MΩ/km] |
| UTP cat. 5e | 1 | a | 8,8·104 |
| b | 1,2·105 | ||
| 2 | a | 9,0·104 | |
| b | 1,6·105 | ||
| 3 | a | 8,1·104 | |
| b | 2,0·105 | ||
| 4 | a | 7,5·104 | |
| b | 1,1·105 | ||
| Required | - | - | ≥50 |
- Tests of electric strength of insulation.
| Test method | Test voltage VAC | |
| Applied (passed) | Required | |
| Voltage applied between connected in parallel all a wires and all b wires | 1000 | 1000 |
- End-to-end attenuation testing.
| Cable | Pair | Effective attenuation [dB] |
| UTP cat. 5e | 1 | 22,9 |
| 2 | 22,8 | |
| 3 | 21,5 | |
| 4 | 21,2 | |
| Required | - | ≤24,9 |
- Near End Cross Talk (NEXT) testing.
| Cable | Pair to pair | NEXT [dB] |
| UTP cat. 5e | 1 - 2 | 43,5 |
| 1 - 3 | 47,9 | |
| 1 - 4 | 45,3 | |
| 2 - 3 | 44,9 | |
| 2 - 4 | 47,8 | |
| 3 - 4 | 41,4 | |
| Required | - | ≥34,0 |
- Return loss testing.
| Cable | Pair | Return loss [dB] |
| UTP cat. 5e | 1 | 20,8 |
| 2 | 21,2 | |
| 3 | 20,9 | |
| 4 | 19,9 | |
| Required | - | ≥19,4 |
- Total Near End Cross Talk (PS-NEXT) testing.
| Cable | Pair | PS-NEXT [dB] |
| UTP cat. 5e | 1 | 36,94 |
| 2 | 33,93 | |
| 3 | 33,63 | |
| 4 | 35,44 | |
| Required | - | ≥31,0 |
Specifications
| Name | NETSET U/UTP cat. 5e | ||
| Product type | twisted-pair cable | ||
| Manufacturer | DIPOL | ||
| Brand | NETSET | ||
| Cable type | U/UTP | ||
| Applications | Indoor | ||
| Category | 5e | ||
| Cable length | m | 305 | |
| CPR class | Eca | ||
| Physical properties | |||
| Conductor | Material | Cooper | |
| Conductor | Diameter | mm | 0.5 |
| Conductor insulation | Material | HDPE (polyethylene) | |
| Conductor insulation | Diameter | mm | 0.87 |
| Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
| sheath | Material | PVC | |
| sheath | Diameter | mm | 5.2 |
| thickness | mm | 0.55 | |
| Color | RAL7032 (gray) | ||
| Gel filled | No | ||
| Carrier cable | No | ||
| Rip-cord | Yes | ||
| Spline | No | ||
| Length marker print error | % | <0.5 | |
| Electrical parameters | |||
| Impedance | Ohm | 100 | |
| Nominal Velocity of Propagation NVP | % | 67 | |
| Delay skew | ns/100 m | <45 | |
| DC resistance | Ohm/100 m | 9.5 | |
| Resistance asymmetry | % | <5 | |
| Return Loss | 1 MHz | ≥dB | 20 |
| Return Loss | 4 MHz | ≥dB | 23 |
| 8 MHz | ≥dB | 24.5 | |
| 10 MHz | ≥dB | 25 | |
| 16 MHz | ≥dB | 25 | |
| 20 MHz | ≥dB | 25 | |
| 25 MHz | ≥dB | 24.3 | |
| 31.25 MHz | ≥dB | 23.6 | |
| 62.5 MHz | ≥dB | 21.5 | |
| 100 MHz | ≥dB | 20.1 | |
| Loss | 1 MHz | ≤dB | 2 |
| Loss | 4 MHz | ≤dB | 4.1 |
| 8 MHz | ≤dB | 5.8 | |
| 10 MHz | ≤dB | 6.5 | |
| 16 MHz | ≤dB | 8.2 | |
| 20 MHz | ≤dB | 9.3 | |
| 25 MHz | ≤dB | 10.4 | |
| 31.25 MHz | ≤dB | 11.7 | |
| 62.5 MHz | ≤dB | 17 | |
| 100 MHz | ≤dB | 22 | |
| NEXT (near-end crosstalk) | 1 MHz | ≤dB | 65.3 |
| NEXT (near-end crosstalk) | 4 MHz | ≤dB | 56.3 |
| 8 MHz | ≤dB | 51.8 | |
| 10 MHz | ≤dB | 50.3 | |
| 16 MHz | ≤dB | 47.2 | |
| 20 MHz | ≤dB | 45.8 | |
| 25 MHz | ≤dB | 44.3 | |
| 31.25 MHz | ≤dB | 42.9 | |
| 62.5 MHz | ≤dB | 38.4 | |
| 100 MHz | ≤dB | 35.3 | |
| PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 62.3 |
| PSNEXT (power sum near-end crosstalk) | 4 MHz | ≥dB | 53.3 |
| 8 MHz | ≥dB | 48.8 | |
| 10 MHz | ≥dB | 47.3 | |
| 16 MHz | ≥dB | 44.4 | |
| 20 MHz | ≥dB | 42.8 | |
| 25 MHz | ≥dB | 41.3 | |
| 31.25 MHz | ≥dB | 39.9 | |
| 62.5 MHz | ≥dB | 35.4 | |
| 100 MHz | ≥dB | 32.3 | |
| ELFEXT | 1 MHz | ≥dB | 63.8 |
| ELFEXT | 4 MHz | ≥dB | 51.8 |
| 8 MHz | ≥dB | 45.7 | |
| 10 MHz | ≥dB | 43.8 | |
| 16 MHz | ≥dB | 39.7 | |
| 20 MHz | ≥dB | 37.8 | |
| 25 MHz | ≥dB | 35.8 | |
| 31.25 MHz | ≥dB | 33.9 | |
| 62.5 MHz | ≥dB | 27.9 | |
| 100 MHz | ≥dB | 23.8 | |
| PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 60.8 |
| PSELFEXT (power sum far-end crosstalk) | 4 MHz | ≥dB | 48.8 |
| 8 MHz | ≥dB | 42.7 | |
| 10 MHz | ≥dB | 40.8 | |
| 16 MHz | ≥dB | 36.7 | |
| 20 MHz | ≥dB | 34.8 | |
| 25 MHz | ≥dB | 32.8 | |
| 31.25 MHz | ≥dB | 30.9 | |
| 62.5 MHz | ≥dB | 24.9 | |
| 100 MHz | ≥dB | 20.8 | |
| Mechanical properties | |||
| Operating temperature | °C | -20...+70 | |
| Installation temperature | °C | 0...+50 | |
| Minimum bending radius for indoor installation | Diameter | >8 | |
Videos
How to attach RJ-45 connector to cat 5 UTP cable? Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.

![CAT 5e UTP Cable: NETSET U/UTP 5e [1m], indoor](https://static.dipol.com.pl/images/images/E1408_CPR_.jpg)