How to attach RJ-45 connector to cat 5 UTP cable? Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.
€0.56
| Price | Disc. | Quantity | Validity |
|---|---|---|---|
| €0.56 | 0 % | from 1 piece |
Available
NETSET U/UTP Category 5e twisted pair cable is the highest quality twisted pair designed for professional outdoor installations.
• Cable type: U/UTP
• Category 5e
• Application: outdoor
• PE sheath
• Core diameter 0.5 mm (24 AWG)
• Cable sold by the metre
• Category 5e
• Application: outdoor
• PE sheath
• Core diameter 0.5 mm (24 AWG)
• Cable sold by the metre
Details
Note: The maximum length of the ordered section is 300 m.
NETSET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
NETSET UTP PE 5e E1412 is a top quality twisted-pair cable designed for professional data transmission systems installed outdoors. Its polyethylene (PE) sheath is resistant to UV radiation (sunlight) and moisture. The cable put into ducts or trays can be used in installations buried in the ground. However, in the case of cabling operating in environments with increased humidity, the better choice is the gel-filled cable - NETSET UTPw 5e E1410.
The introduction of a new generation of IP cameras in recent years has increased the requirements for the transmission medium UTP category 5e. The production of high-resolution cameras has significantly increased the demand for bandwidth, multiplying the amount of transmitted data. For this reason, twisted-pair crosstalk parameters become such an important criterion for twisted-pair cable selection.
In response to market demand, DIPOL has introduced a family of twisted-pair cables with the highest parameters under the common name NETSET.
In response to market demand, DIPOL has introduced a family of twisted-pair cables with the highest parameters under the common name NETSET.
The outer diameter of the NETSET UTP PE 5e cable has been reduced to 6.0 mm, which considerably facilitates laying of the cable in ducts and pipes. The insulation of the wires has been made of special PE, to make it easier to crimp RJ-45 connectors onto the cable.
Distinguishing features of NETSET UTP PE 5e cable:
- highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee
- preliminary quality control of materials and thorough tests of the final product
- meter markers - length error less than 0.5%
- solid wires of 0.50 mm diameter (24 AWG)
- wire insulation made of homogeneous, colored PE; outer diameter: 1.01 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue
- insulated wires twisted in pairs of 2.02 mm diameter
- pairs twisted together
- sheath made of black PE, outer diameter of 6.0 mm
NETSET UTP PE 5e E1412 cable is manufactured in compliance with EN 50173, ISO/IEC 61156-5 edition: 2002, ISO/IEC 11801 standards.
NETSET cables come with a 15-year warranty.
The manufacturer guarantees the stability of the parameters for a period of 15 years. The condition for maintenance of the guarantee is observance of the principles of packaging, storage and transport described in the PN-70 E-79100 standard and the principles of operation described in the PN-EN 50174-1 standard.
NETSET UTP PE 5e E1412 cable can be used in a wide temperature range: -20o...+50oC, and installed between -30o...+50 oC.
The cable is also available in unreel box - E1412_305.
NETSET BOX UTP CAT 5e cable has been tested by
Central Chamber for Telecommunications Testing of
National Institute of Telecommunications in Warsaw, Poland
and got
CERTIFICATE OF THE INSTITUTE
The results of the measurements of the NETSET BOX UTP PE 5e cable conducted by the
National Institute of Telecommunications in Warsaw, Poland
The results of NETSET BOX UTP CAT 5e tests performed by
National Institute of Telecommunications in Warsaw
- Pair resistance testing.
| Pair | Wire | Wire resistance [Ω/km] | Resistance asymmetry [%] | |
| UTP cat. 5e PE | 1 | a | 87.320 | 0.22 |
| b | 87.136 | |||
| 2 | a | 84.663 | 0.20 | |
| b | 84.831 | |||
| 3 | a | 85.082 | 0.21 | |
| b | 84.903 | |||
| 4 | a | 86.035 | 0.18 | |
| b | 86.192 | |||
| Required | - | - | ≤150 | ≤3.0 |
- +++ Checking effective capacitance and capacitance asymmetry.
| Pair | Effective capacitance [nF/km] | Capacitance asymmetry [pF/km] | |
| UTP cat. 5e PE | 1 | 51.74 | 208 |
| 2 | 49.21 | 116 | |
| 3 | 49.79 | 7 | |
| 4 | 50.85 | 13 | |
| Required | - | ≤55 | ≤1600 |
- Insulation testing.
| Pair | Wire | Insulation resistance [MΩ/km] | |
| UTP kat. 5e PE | 1 | a | 4.5 · 105 |
| b | 4.8 · 105 | ||
| 2 | a | 6.6 · 105 | |
| b | 4.6 · 105 | ||
| 3 | a | 4.9 · 105 | |
| b | 5.8 · 105 | ||
| 4 | a | 4.5 · 105 | |
| b | 7.0 · 104 | ||
| Required | - | - | ≥150 |
- Tests of electric strength of insulation.
| Test method | Test voltage [VAC] | |
| Applied (passed) | Required | |
| Voltage applied between connected in parallel all a wires and all b wires | 1000 | 1000 |
- End-to-end attenuation testing.
| Pair | Effective attenuation [dB] | |
| UTP cat. 5e PE | 1 | 21.2 |
| 2 | 20.8 | |
| 3 | 20.5 | |
| 4 | 21.2 | |
| Required | - | ≤24.9 |
- Near End Cross Talk (NEXT) testing.
| Pair to pair | NEXT [dB] | |
| UTP cat. 5e PE | 1-2 | 47.3 |
| 1-3 | 52.6 | |
| 1-4 | 55.4 | |
| 2-3 | 54.8 | |
| 2-4 | 55.5 | |
| 3-4 | 60.2 | |
| Required | - | ≥34.0 |
- Return loss testing.
| Pair | Return loss [dB] | |
UTP cat. 5e PE | 1 | 20.7 |
| 2 | 21.8 | |
| 3 | 22.4 | |
| 4 | 21.5 | |
| Required | - | ≥19.4 |
- Total Near End Cross Talk (PS-NEXT) testing.
| Pair | PS-NEXT [dB] | |
| UTP cat. 5e PE | 1 | 45.69 |
| 2 | 46.07 | |
| 3 | 50.11 | |
| 4 | 51.77 | |
| Required | - | ≥31.0 |
The parameters show that NETSET BOX UTP PE 5e fulfills all requirements for Category 5e cables, with a large safety margin.
Price for 1 m.
Specifications
| Name | NETSET U/UTP Cat. 5e outdoor | ||
| Product type | twisted-pair cable | ||
| Manufacturer | DIPOL | ||
| Brand | NETSET | ||
| Cable type | U/UTP | ||
| Applications | Outdoor | ||
| Category | 5e | ||
| Cable length | m | Sold per meter | |
| CPR class | FCA | ||
| Physical properties | |||
| Conductor | Material | Cooper | |
| Conductor | Diameter | mm | 0.5 |
| Conductor insulation | Material | HDPE (polyethylene) | |
| Conductor insulation | Diameter | mm | 0.87 |
| Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
| sheath | Material | LDPE | |
| sheath | Diameter | mm | 5.2 |
| thickness | mm | 0.55 | |
| Color | RAL9005 (black) | ||
| Gel filled | No | ||
| Carrier cable | No | ||
| Rip-cord | Yes | ||
| Spline | No | ||
| Length marker print error | % | <0.5 | |
| Electrical parameters | |||
| Impedance | Ohm | 100 | |
| Nominal Velocity of Propagation NVP | % | 67 | |
| Delay skew | ns/100 m | <45 | |
| DC resistance | Ohm/100 m | 9.5 | |
| Resistance asymmetry | % | <5 | |
| Return Loss | 1 MHz | ≥dB | 20 |
| Return Loss | 4 MHz | ≥dB | 23 |
| 8 MHz | ≥dB | 24.5 | |
| 10 MHz | ≥dB | 25 | |
| 16 MHz | ≥dB | 25 | |
| 20 MHz | ≥dB | 25 | |
| 25 MHz | ≥dB | 24.3 | |
| 31.25 MHz | ≥dB | 23.6 | |
| 62.5 MHz | ≥dB | 21.5 | |
| 100 MHz | ≥dB | 20.1 | |
| Loss | 1 MHz | ≤dB | 2 |
| Loss | 4 MHz | ≤dB | 4.1 |
| 8 MHz | ≤dB | 5.8 | |
| 10 MHz | ≤dB | 6.5 | |
| 16 MHz | ≤dB | 8.2 | |
| 20 MHz | ≤dB | 9.3 | |
| 25 MHz | ≤dB | 10.4 | |
| 31.25 MHz | ≤dB | 11.7 | |
| 62.5 MHz | ≤dB | 17 | |
| 100 MHz | ≤dB | 22 | |
| NEXT (near-end crosstalk) | 1 MHz | ≤dB | 65.3 |
| NEXT (near-end crosstalk) | 4 MHz | ≤dB | 56.3 |
| 8 MHz | ≤dB | 51.8 | |
| 10 MHz | ≤dB | 50.3 | |
| 16 MHz | ≤dB | 47.2 | |
| 20 MHz | ≤dB | 45.8 | |
| 25 MHz | ≤dB | 44.3 | |
| 31.25 MHz | ≤dB | 42.9 | |
| 62.5 MHz | ≤dB | 38.4 | |
| 100 MHz | ≤dB | 35.3 | |
| PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 62.3 |
| PSNEXT (power sum near-end crosstalk) | 4 MHz | ≥dB | 53.3 |
| 8 MHz | ≥dB | 48.8 | |
| 10 MHz | ≥dB | 47.3 | |
| 16 MHz | ≥dB | 44.4 | |
| 20 MHz | ≥dB | 42.8 | |
| 25 MHz | ≥dB | 41.3 | |
| 31.25 MHz | ≥dB | 39.9 | |
| 62.5 MHz | ≥dB | 35.4 | |
| 100 MHz | ≥dB | 32.3 | |
| ELFEXT | 1 MHz | ≥dB | 63.8 |
| ELFEXT | 4 MHz | ≥dB | 51.8 |
| 8 MHz | ≥dB | 45.7 | |
| 10 MHz | ≥dB | 43.8 | |
| 16 MHz | ≥dB | 39.7 | |
| 20 MHz | ≥dB | 37.8 | |
| 25 MHz | ≥dB | 35.8 | |
| 31.25 MHz | ≥dB | 33.9 | |
| 62.5 MHz | ≥dB | 27.9 | |
| 100 MHz | ≥dB | 23.8 | |
| PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 60.8 |
| PSELFEXT (power sum far-end crosstalk) | 4 MHz | ≥dB | 48.8 |
| 8 MHz | ≥dB | 42.7 | |
| 10 MHz | ≥dB | 40.8 | |
| 16 MHz | ≥dB | 36.7 | |
| 20 MHz | ≥dB | 34.8 | |
| 25 MHz | ≥dB | 32.8 | |
| 31.25 MHz | ≥dB | 30.9 | |
| 62.5 MHz | ≥dB | 24.9 | |
| 100 MHz | ≥dB | 20.8 | |
| Mechanical properties | |||
| Operating temperature | °C | -20...+70 | |
| Installation temperature | °C | -30...+50 | |
| Minimum bending radius for indoor installation | Diameter | >8 | |