A short instructional video on crimping RJ-45 connector on a category 6 UTP cable, according to the EIA/EIA 568B standard. The items used: NETSET U/UTP cat. 6 cable, 8-pin RJ-45 modular plug, modular plug boot, HT-210N crimping tool, cable tester NS-468AT.
| Price | Disc. | Quantity | Validity |
|---|---|---|---|
| €332.68 | 0 % | from 1 piece |
• Category 6
• Uses: indoors
• LSZH sheath
• Fire class B2ca-s1a-d1-a1
• Conductor diameter 0.55 mm (24 AWG)
Details
- top quality materials, made to tight specifications, proven with a, 15-year quality guarantee
- flammability class B2ca-s1a-d1-a1
- preliminary quality control of materials and thorough tests of the finished product
- meter markers
- cooper solid wires diameter 0.565 mm
- insulation of conductors made of insulating, mass-coloured HDPE, conductor diameter: 0.98 mm, insulation colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue
- cable sheath made of LSZH compliant material, outer diameter 6.4 mm
- length marker print error max. 0.5%
EN50575:2014, EN60332-1-2:2004, EN50399:2011, EN60754-2:2014, EN 13501-6:2014.

- Return Loss
| Frequency [MHz] | Result (min.) [dB] |
| 1 | 20.0 |
| 4 | 23.0 |
| 8 | 24.5 |
| 10 | 25.0 |
| 16 | 25.0 |
| 20 | 25.0 |
| 25 | 24.3 |
| 31.25 | 23.6 |
| 62.5 | 21.5 |
| 100 | 20.1 |
| 200 | 18 |
| 250 | 17.3 |
- Attenuation
| Frequency [MHz] | Result (min.) [dB] |
| 1 | 2,03 |
| 4 | 3,78 |
| 8 | 5,32 |
| 10 | 5,95 |
| 16 | 8,47 |
| 25 | 9,51 |
| 31,25 | 10,67 |
| 62,5 | 15,38 |
| 100 | 19,8 |
| 200 | 28,98 |
| 250 | 32,85 |
- NEXT (near end crosstalk)
| Frequency [MHz] | Result (min.) [dB] |
| 1 | 74.3 |
| 4 | 65.3 |
| 8 | 60.8 |
| 10 | 59.3 |
| 16 | 56.2 |
| 20 | 54.8 |
| 25 | 53.3 |
| 31.25 | 51.9 |
| 62.5 | 47.7 |
| 100 | 44.3 |
| 200 | 39.8 |
| 250 | 38.3 |
- PSNEXT (power sum near end crosstalk)
| Frequency [MHz] | Result (min.) [dB] |
| 1 | 72,3 |
| 4 | 63,3 |
| 8 | 58,8 |
| 10 | 57,3 |
| 16 | 54,2 |
| 20 | 51,3 |
| 31,25 | 49,9 |
| 62,5 | 45,4 |
| 100 | 42,3 |
| 200 | 37,8 |
| 250 | 36,3 |
- ELFEXT (equal level far end crosstalk loss testing)
| Frequency [MHz] | Result (min.) [dB] |
| 1 | 67,8 |
| 4 | 55,8 |
| 8 | 49,7 |
| 10 | 47,8 |
| 16 | 43,7 |
| 20 | 41,8 |
| 25 | 39,8 |
| 31,25 | 37,9 |
| 62,5 | 31,9 |
| 100 | 27,8 |
| 200 | 21,8 |
| 250 | 19,8 |
- PSELFEXT (power sum equal level far end crosstalk loss testing)
| Frequency [MHz] | Result (min.) [dB] |
| 1 | 64.8 |
| 4 | 52.8 |
| 8 | 46.7 |
| 10 | 44.8 |
| 16 | 40.7 |
| 20 | 38.8 |
| 25 | 36.8 |
| 31.25 | 34.9 |
| 62.5 | 28.9 |
| 100 | 24.8 |
| 200 | 18.8 |
| 250 | 16.8 |
Specifications
| Name | NETSET U/UTP cat. 6 | ||
| Product type | twisted-pair cable | ||
| Manufacturer | DIPOL | ||
| Brand | NETSET | ||
| Cable type | U/UTP | ||
| Applications | Indoor | ||
| Category | 6 | ||
| Cable length | m | 500 | |
| CPR class | B2ca s1a,d1,a1 | ||
| Physical properties | |||
| Conductor | Material | Cooper | |
| Conductor | Diameter | mm | 0.55 |
| Conductor insulation | Material | HDPE (polyethylene) | |
| Conductor insulation | Diameter | mm | 0.98 |
| Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
| Twisted pair shield | Material | Al/Mylar | |
| sheath | Diameter | mm | 6.4 |
| thickness | mm | 0.75 | |
| Color | RAL7032 (gray) | ||
| Gel filled | No | ||
| Carrier cable | No | ||
| Rip-cord | Yes | ||
| Spline | No | ||
| Length marker print error | % | <0.5 | |
| Electrical parameters | |||
| Impedance | Ohm | 100 | |
| Delay skew | ns/100 m | <45 | |
| Asymmetry in capacitance of transmission paths to the ground | pF/100 m | 330 | |
| DC resistance | Ohm/100 m | 9.38 | |
| Resistance asymmetry | % | <5 | |
| Return Loss | 1 MHz | ≥dB | 20 |
| Return Loss | 4 MHz | ≥dB | 23 |
| 8 MHz | ≥dB | 24.5 | |
| 10 MHz | ≥dB | 25 | |
| 16 MHz | ≥dB | 25 | |
| 20 MHz | ≥dB | 25 | |
| 25 MHz | ≥dB | 24.3 | |
| 31.25 MHz | ≥dB | 23,6 | |
| 62.5 MHz | ≥dB | 21.5 | |
| 100 MHz | ≥dB | 20.1 | |
| 200 MHz | ≥dB | 18 | |
| 250 MHz | ≥dB | 17.3 | |
| Loss | 1 MHz | ≤dB | 2 |
| Loss | 4 MHz | ≤dB | 3.78 |
| 8 MHz | ≤dB | 5.32 | |
| 10 MHz | ≤dB | 5.95 | |
| 16 MHz | ≤dB | 8.47 | |
| 20 MHz | ≤dB | 9.3 | |
| 25 MHz | ≤dB | 9.51 | |
| 31.25 MHz | ≤dB | 10.67 | |
| 62.5 MHz | ≤dB | 15.38 | |
| 100 MHz | ≤dB | 19.8 | |
| 200 MHz | ≤dB | 28.98 | |
| 250 MHz | ≤dB | 32.85 | |
| NEXT (near-end crosstalk) | 1 MHz | ≤dB | 74.3 |
| NEXT (near-end crosstalk) | 4 MHz | ≤dB | 65.3 |
| 8 MHz | ≤dB | 60.8 | |
| 10 MHz | ≤dB | 59.3 | |
| 16 MHz | ≤dB | 56.2 | |
| 20 MHz | ≤dB | 54.8 | |
| 25 MHz | ≤dB | 53.3 | |
| 31.25 MHz | ≤dB | 51.9 | |
| 62.5 MHz | ≤dB | 47.7 | |
| 100 MHz | ≤dB | 44.3 | |
| 200 MHz | ≤dB | 39.8 | |
| 250 MHz | ≤dB | 38.3 | |
| PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 72.3 |
| PSNEXT (power sum near-end crosstalk) | 4 MHz | ≥dB | 63.3 |
| 8 MHz | ≥dB | 58.8 | |
| 10 MHz | ≥dB | 57.3 | |
| 16 MHz | ≥dB | 54.2 | |
| 20 MHz | ≥dB | 52.8 | |
| 25 MHz | ≥dB | 51.3 | |
| 31.25 MHz | ≥dB | 49.9 | |
| 62.5 MHz | ≥dB | 45.4 | |
| 100 MHz | ≥dB | 42.3 | |
| 200 MHz | ≥dB | 37.8 | |
| 250 MHz | ≥dB | 36.3 | |
| ELFEXT | 1 MHz | ≥dB | 67.8 |
| ELFEXT | 4 MHz | ≥dB | 55.8 |
| 8 MHz | ≥dB | 49.7 | |
| 10 MHz | ≥dB | 47.8 | |
| 16 MHz | ≥dB | 43.7 | |
| 20 MHz | ≥dB | 41.8 | |
| 25 MHz | ≥dB | 39.8 | |
| 31.25 MHz | ≥dB | 37.9 | |
| 62.5 MHz | ≥dB | 31.9 | |
| 100 MHz | ≥dB | 27.8 | |
| 200 MHz | ≥dB | 21.8 | |
| 250 MHz | ≥dB | 19.8 | |
| PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 64.8 |
| PSELFEXT (power sum far-end crosstalk) | 4 MHz | ≥dB | 52.8 |
| 8 MHz | ≥dB | 46.7 | |
| 10 MHz | ≥dB | 44.8 | |
| 16 MHz | ≥dB | 40.7 | |
| 20 MHz | ≥dB | 38.8 | |
| 25 MHz | ≥dB | 36.8 | |
| 31.25 MHz | ≥dB | 34.9 | |
| 62.5 MHz | ≥dB | 28.9 | |
| 100 MHz | ≥dB | 24.8 | |
| 200 MHz | ≥dB | 18.8 | |
| 250 MHz | ≥dB | 16.8 | |
| Mechanical properties | |||
| Operating temperature | °C | -20...+70 | |
| Installation temperature | °C | 0...+50 | |
| Minimum bending radius for indoor installation | Diameter | >8 | |
| Packaging | |||
| Spool | Diameter | mm | 380 |
| Spool | Width | mm | 385 |
| spool hole diameter | mm | 33 | |
Videos
How to attach RJ-45 connector to cat 5 UTP cable? Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.