CAT 6 UTP Cable: NETSET BOX U/UTP PE (outdoor) [1m]

Code: E1610_1
€0.75
Price Disc. Quantity Validity
€0.75 0 % from 1 piece
Available
NETSET BOX U/UTP PE Cat. 6 E1610 is a top quality twisted-pair cable designed for professional data transmission systems installed outdoors.

Warranty

15-year warranty.

Support

Details

NETSET BOX U/UTP PE Cat. 6 E1610 is a top quality twisted-pair cable designed for professional data transmission systems installed outdoors. Its polyethylene (PE) sheath is resistant to UV radiation (sunlight) and moisture. The cable put into ducts or trays can be used in installations buried in the ground.
The outer diameter of the NETSET U/UTP Cat. 6 cable has been reduced to 6.1 mm, which considerably facilitates laying of the cable in ducts and pipes. The insulation of the wires has been made of special PE, to make it easier to crimp RJ-45 connectors onto the cable.
Distinguishing features of NETSET BOX U/UTP PE Cat. 6 cable:
  • highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
  • preliminary quality control of materials and thorough tests of the final product,
  • meter markers, length error less than 0.5%,
  • solid wires of 0.54 mm diameter (24 AWG),
  • wire insulation made of homogeneous, colored PE; outer diameter: 0.94 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
  • insulated wires twisted in pairs of 2.02 mm diameter,
  • sheath made of black PE, outer diameter of 6.0 mm.
The NETSET U/UTP PE Cat. 6 E1610 cable is manufactured in compliance with EN50575:2014 standard.
The cable comes with a 15-year warranty.
The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET BOX U/UTP PE Cat. 6 E1610 cable can be used in a wide temperature range: -20o...+50oC, and installed between -30o...+50 oC.
Test results
  • Return Loss
Frequency [MHz] Result (min.) [dB]
1 20,0
4 23,0
8 24,5
10 25,0
16 25,0
20 25,0
25 24,3
31,25 23,6
62,5 21,5
100 20,1
200 18,0
250 17,3
  • Attenuation
Frequency [MHz] Result (max.) [dB]
1 2,03
4 3,78
8 5,32
10 5,95
16 7,55
20 8,47
25 9,51
31,25 10,67
62,5 15,38
100 19,80
200 28,98
250 32,85

  • NEXT (near end crosstalk)
Frequency [MHz] Result (min.) [dB]
1 74.3
4 65.3
8 60.8
10 59.3
16 56.2
20 54.8
25 53.3
31.25 51.9
62.5 47.7
100 44.3
200 39.8
250 38.3

  • PSNEXT (power sum near end crosstalk)
Frequency [MHz] Result (min.) [dB]
1  72,3
4  63,3
8  58,8
10  57,3
16  54,2
20  52,8
25  51,3
31,25  49,9
62,5  45,4
100  42,3
200  37,8
250 36,3 

  • ELFEXT (equal level far end crosstalk loss testing)
Frequency [MHz] Result (min.) [dB]
1  67,8
4 55,8
8  49,7
10  47,8
16  43,7
20  41,8
25  39,8
31,25  37,9
62,5  31,9
100  27,8
200  21,8
250  19,8

 


  • PSELFEXT (power sum equal level far end crosstalk loss testing)
Frequency [MHz] Result (min.) [dB]
1 64.8
4 52.8
8 46.7
10 44.8
16 40.7
20 38.8
25 36.8
31.25 34.9
62.5 28.9
100 24.8
200 18.8
250 16.8
The parameters show that the NETSET BOX U/UTP PE Cat. 6 cable fulfills all requirements for Category 6 cables, with a large safety margin.

Specifications

Name NETSET U/UTP cat. 6 external
Product type twisted-pair cable
Manufacturer Dipol
Brand NETSET
Cable type U/UTP
Applications Outdoor
Category 6
Cable length m Sold per meter
CPR class FCA
Physical properties
Conductor Material Cooper
Diameter mm 0.54
Conductor insulation Material HDPE (polyethylene)
Diameter mm 0.94
Twisted pairs colors white-brown/brown, white-blue/blue, white-orange/orange, white-green/green
sheath Material LDPE
Diameter mm 6.1
thickness mm 0.55
Color RAL9005 (black)
Gel filled No
Carrier cable No
Rip-cord Yes
Spline Yes
Length marker print error % <0.5
Electrical parameters
Impedance Ohm 100
Nominal Velocity of Propagation NVP % 67
Delay skew ns/100 m <45
DC resistance Ohm/100 m 9.38
Resistance asymmetry % <5
Return Loss 1 MHz ≥dB 20
4 MHz ≥dB 23
8 MHz ≥dB 24.5
10 MHz ≥dB 25
16 MHz ≥dB 25
20 MHz ≥dB 25
25 MHz ≥dB 24.3
31.25 MHz ≥dB 23.6
62.5 MHz ≥dB 21.5
100 MHz ≥dB 20.1
200 MHz ≥dB 18
250 MHz ≥dB 17.3
Loss 1 MHz ≤dB 2
4 MHz ≤dB 3.78
8 MHz ≤dB 5.32
10 MHz ≤dB 5.95
16 MHz ≤dB 7.55
20 MHz ≤dB 8.47
25 MHz ≤dB 9.51
31.25 MHz ≤dB 10.67
62.5 MHz ≤dB 15.38
100 MHz ≤dB 19.8
200 MHz ≤dB 28.98
250 MHz ≤dB 32.85
NEXT (near-end crosstalk) 1 MHz ≤dB 74.3
4 MHz ≤dB 65.3
8 MHz ≤dB 60.8
10 MHz ≤dB 59.3
16 MHz ≤dB 56.2
20 MHz ≤dB 54.8
25 MHz ≤dB 53.3
31.25 MHz ≤dB 51.9
62.5 MHz ≤dB 47.7
100 MHz ≤dB 44.3
200 MHz ≤dB 39.8
250 MHz ≤dB 38.3
PSNEXT (power sum near-end crosstalk) 1 MHz ≥dB 72.3
4 MHz ≥dB 63.3
8 MHz ≥dB 58.8
10 MHz ≥dB 57.3
16 MHz ≥dB 54.2
20 MHz ≥dB 52.8
25 MHz ≥dB 51.3
31.25 MHz ≥dB 49.9
62.5 MHz ≥dB 45.4
100 MHz ≥dB 42.3
200 MHz ≥dB 37.8
250 MHz ≥dB 36.3
ELFEXT 1 MHz ≥dB 67.8
4 MHz ≥dB 55.8
8 MHz ≥dB 49.7
10 MHz ≥dB 47.8
16 MHz ≥dB 43.7
20 MHz ≥dB 41.8
25 MHz ≥dB 39.8
31.25 MHz ≥dB 37.9
62.5 MHz ≥dB 31.9
100 MHz ≥dB 27.8
200 MHz ≥dB 21.8
250 MHz ≥dB 19.8
PSELFEXT (power sum far-end crosstalk) 1 MHz ≥dB 64.8
4 MHz ≥dB 52.8
8 MHz ≥dB 46.7
10 MHz ≥dB 44.8
16 MHz ≥dB 40.7
20 MHz ≥dB 38.8
25 MHz ≥dB 36.8
31.25 MHz ≥dB 34.9
62.5 MHz ≥dB 28.9
100 MHz ≥dB 24.8
200 MHz ≥dB 18.8
250 MHz ≥dB 16.8
Mechanical properties
Operating temperature °C -20...+70
Installation temperature °C -30...+50
Minimum bending radius for indoor installation Diameter >8

Videos

RJ45 plug on UTP cable - Installing

How to attach RJ-45 connector to cat 5 UTP cable? Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.