Support
Details
NETSET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
NETSET U/FTP 6A is a top quality indoor FTP CAT 6A twisted-pair cable designed for use in professional computer networks inside buildings. Shielding layers made of aluminum foil minimize crosstalk between pairs and interference with the external environment.
- highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
- parameters far exceeding the requirements for Category 6A twisted pair cables,
- preliminary quality control of materials and thorough tests of the final product,
- solid wires of 0.57 mm diameter (23 AWG),
- wire insulation made of Skin-foam-skin PE; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
- insulated wires twisted in pairs, shielded with aluminum foil,
- sheath made of LSZH material of 7.4 mm diameter,
- meter markers - length error less than 0.5%.
1 - white-blue/blue wire
2 - white-brown/brown wire
3 - white-green/green wire
4 - white-orange/orange
5 - drain wire
6 - Rip-cord
7 - aluminum shielding
8 - sheath (jacket)
2 - white-brown/brown wire
3 - white-green/green wire
4 - white-orange/orange
5 - drain wire
6 - Rip-cord
7 - aluminum shielding
8 - sheath (jacket)
NETSET U/FTP 6A E1616 cable is compliant with the following standards:
- General requirements for 6A category
- ISO/IEC 11801:2011 (Ed. 2.2)
- IEC 61156-5:2012 (Ed. 2.1)
- EN 50173-1:2011
- EN 50173-2:2007 A1:2010
- EN 50288-10-1:2012
- ANSI/TIA-568-C.2:2009
- Flammability
- IEC 60332-1-1:2015 (Ed. 1.1) / IEC 60332-1-2:2015 (Ed. 1.1)
- IEC 60754-1:2011 (Ed. 3.0) / IEC 60754-2:2011 (Ed. 2.0)
- IEC 61034-1:2013 (Ed. 3.1) / IEC 61034-2:2013 (Ed. 3.1)
- Reaction to fire
- Eca classification
- EN 50575:2014 including amendment A1:2016
- EN 60332-1-2:2004 including amendment A1:2015
- EN 13501-6:2014
The cable comes with a 15-year warranty.
The manufacturer guarantees stability of parameters at least for 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET U/FTP CAT 6A E1616 cable can be used in a wide temperature range: -30oC...+50oC, and installed between 0oC and +50oC. The bending radius should be at least 8 times greater than the outer diameter of the cable.
Specifications
Name | NETSET U/FTP 6A | |||||||||
Code | E1616 | |||||||||
STRUCTURE | ||||||||||
Wires | solid copper conductors Ø 0.57 mm (23 AWG) | |||||||||
Wire insulation | Skin-foam-skin PE, diam. 1.35 mm | |||||||||
Shielding | Aluminum foil, thickness of 0.45 mm | |||||||||
Sheath | LSZH material thickness of 0.55 mm ext. diam. of 7.4 mm black | |||||||||
MARKINGS
| ||||||||||
ELECTRICAL PARAMETERS | ||||||||||
Wave impedance [Ω] | 100 ±15 | |||||||||
Nominal Velocity of Propagation (NVP) [%] | 74 | |||||||||
Delay skew [ns/100m] | ≤ 45 | |||||||||
Asymmetry in capacitance of transmission paths to the ground [pF/100m] | max 330 | |||||||||
DC resistance [Ω/100m] | 9.38 | |||||||||
INSTALLATION AND OPERATION | ||||||||||
Operating temperature range [°C] | -30...+50 | |||||||||
Installation temperature range [°C] | 0...+50 | |||||||||
Minimum bending radius [radius to diameter ratio] | >8 |
Test results
- Return Loss
Frequency [MHz] | Result [dB] |
1 | 20 |
4 | 23 |
8 | 24.5 |
10 | 25 |
16 | 25 |
20 | 25 |
25 | 24.3 |
31.25 | 23.6 |
62.5 | 21.5 |
100 | 20.1 |
200 | 18 |
250 | 17.3 |
300 | 16.8 |
500 | 15.2 |
The return loss graph of the cable compared with the EN 50173 standard.
- Attenuation
Frequency [MHz] | Result [dB/100m] | |
1 | 2.1 | |
4 | 3.8 | |
8 | 5.3 | |
10 | 5.9 | |
16 | 7.5 | |
20 | 8.4 | |
25 | 9.4 | |
31.25 | 10.5 | |
62.5 | 15 | |
100 | 19.1 | |
200 | 27.6 | |
250 | 31.1 | |
300 | 34.3 | |
500 | 45.3 |
- NEXT
Frequency [MHz] | Result [dB] |
1 | 74.3 |
4 | 65.3 |
8 | 60.8 |
10 | 59.3 |
16 | 56.2 |
20 | 54.8 |
25 | 53.3 |
31.25 | 51.9 |
62.5 | 47.4 |
100 | 44.3 |
200 | 39.8 |
250 | 38.3 |
300 | 37.1 |
500 | 33.8 |
The NEXT (near end crosstalk) graph of the cable compared with the EN 50173 standard.
- PSNEXT
Frequency [MHz] | Result [dB] |
1 | 72.3 |
4 | 63.3 |
8 | 58.8 |
10 | 57.3 |
16 | 54.2 |
20 | 52.8 |
25 | 51.3 |
31.25 | 49.9 |
62.5 | 45.4 |
100 | 42.3 |
200 | 37.8 |
250 | 36.3 |
300 | 35.1 |
500 | 31.8 |
The PSNEXT (power sum near end crosstalk) graph of the cable compared with the EN 50173 standard.
- ELFEXT
Frequency [MHz] | Result [dB] |
1 | 68 |
4 | 56 |
8 | 49.9 |
10 | 48 |
16 | 43.9 |
20 | 42 |
25 | 40 |
31.25 | 38.1 |
62.5 | 32.1 |
100 | 28 |
200 | 22 |
250 | 20 |
300 | 18.5 |
500 | 14 |
The ELFEXT graph of the cable compared with the EN 50173 standard.
- PSELFEXT
Frequency [MHz] | Result [dB] |
1 | 65 |
4 | 53 |
8 | 46.9 |
10 | 45 |
16 | 40.9 |
20 | 39 |
25 | 37 |
31.25 | 35.1 |
62.5 | 29.1 |
100 | 25 |
200 | 19 |
250 | 17 |
300 | 15.5 |
500 | 11 |
The PSELFEXT graph of the cable compared with the EN 50173 standard.
Specifications
Częstotliwość [MHz] | Wynik [>dB] |
1 | 20 |
4 | 23 |
8 | 24,5 |
10 | 25 |
16 | 25 |
20 | 25 |
25 | 24,3 |
31,25 | 23,6 |
62,5 | 21,5 |
100 | 20,1 |
200 | 18 |
250 | 17,3 |
300 | 16,8 |
500 | 15,2 |