Cat 6a U/UTP cable: NETSET U/FTP 6A B2ca s1a,d1,a1 /500m/

Code: E1617_500
€395.73
Price Disc. Quantity Validity
€395.73 0 % from 1 piece
Available
NETSET U/FTP Category 6A twisted pair cable is the highest quality twisted pair cable designed for professional indoor installations.
• Cable type: U/FTP
• Category 6A
• Application: interior
• Flammability class B2ca s1a,d1,a1
• Conductor diameter 0.57 mm (23 AWG)
• Roll of 500 m

Warranty

15-year warranty.

Support

Details

NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables for use in construction works.
NETSET U/FTP 6A is a top quality indoor FTP CAT 6A twisted-pair cable designed for use in professional computer networks inside buildings. Shielding layers made of aluminum foil minimize crosstalk between pairs and interference with the external environment.
Distinguishing features of NETSET U/FTP CAT 6A E1616 cable:
  • highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
  • parameters far exceeding the requirements for Category 6A twisted pair cables,
  • preliminary quality control of materials and thorough tests of the final product,
  • solid wires of 0.57 mm diameter (23 AWG),
  • wire insulation made of Skin-foam-skin PE; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
  • insulated wires twisted in pairs, shielded with aluminum foil,
  • sheath made of LSZH material of 7.4 mm diameter,
  • meter markers - length error less than 0.5%.
1 - white-blue/blue wire
2 - white-brown/brown wire
3 - white-green/green wire
4 - white-orange/orange
5 - drain wire
6 - Rip-cord
7 - aluminum shielding
8 - sheath (jacket)

The NETSET U/FTP cat. 6A E1617 twisted pair cable has been manufactured in accordance with the standards:
  • General requirements for category 6A
    • ISO/IEC 11801:2011 (Ed. 2.2)
    • IEC 61156-5:2012 (Ed. 2.1)
    • EN 50173-1:2011
    • EN 50173-2:2007 A1:2010
    • EN 50288-10-1:2012
    • ANSI/TIA-568-C.2:2009
  • Flammability standards
    • IEC 60332-1-1:2015 (Ed. 1.1) / IEC 60332-1-2:2015 (Ed. 1.1)
    • IEC 60754-1:2011 (Ed. 3.0) / IEC 60754-2:2011 (Ed. 2.0)
    • IEC 61034-1:2013 (Ed. 3.1) / IEC 61034-2:2013 (Ed. 3.1)
  • Reaction to fire
    • Classification B2ca-s1a-d1-a1
    • EN 50575:2014 including amendment A1:2016
    • EN 60332-1-2:2004 including amendment A1:2015
    • EN 13501-6:2014
The cable comes with a 15-year warranty.

The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET U/FTP Category 6A E1617 twisted pair cable is intended for use in an environment with temperature from -30oC to +50 oC. Installation temperature not lower than 0oC and not higher than +50oC. The bending radius should not be less than 8 times the outside diameter.
NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables for use in construction works.
Test results
  • Return Loss
Frequency [MHz] Result [dB]
1 20
4 23
8 24.5
10 25
16 25
20 25
25 24.3
31.25 23.6
62.5 21.5
100 20.1
200 18
250 17.3
300 16.8
500 15.2
  • Attenuation
Frequency [MHz] Result [dB/100m]  
1 2.1  
4 3.8  
8 5.3  
10 5.9  
16 7.5  
20 8.4  
25 9.4  
31.25 10.5  
62.5 15  
100 19.1  
200 27.6  
250 31.1  
300 34.3  
500 45.3  

Frequency [MHz] Result [dB]
1 74.3
4 65.3
8 60.8
10 59.3
16 56.2
20 54.8
25 53.3
31.25 51.9
62.5 47.4
100 44.3
200 39.8
250 38.3
300 37.1
500 33.8
  • PSNEXT
Frequency [MHz] Result [dB]
1 72.3
4 63.3
8 58.8
10 57.3
16 54.2
20 52.8
25 51.3
31.25 49.9
62.5 45.4
100 42.3
200 37.8
250 36.3
300 35.1
500 31.8
  • ELFEXT
Frequency [MHz] Result [dB]
1 68
4 56
8 49.9
10 48
16 43.9
20 42
25 40
31.25 38.1
62.5 32.1
100 28
200 22
250 20
300 18.5
500 14

Frequency [MHz] Result [dB]
1 65
4 53
8 46.9
10 45
16 40.9
20 39
25 37
31.25 35.1
62.5 29.1
100 25
200 19
250 17
300 15.5
500 11

Specifications

Name NETSET U/FTP cat. 6A
Product type twisted-pair cable
Manufacturer Dipol
Brand NETSET
Cable type U/FTP
Applications Indoor
Category 6A
Cable length m 500
CPR class B2ca s1a,d1,a1
Physical properties
Conductor Material Cooper
Conductor Diameter mm 0.560
Conductor insulation Material PE
Conductor insulation Diameter mm 1.33
Twisted pairs colors white-brown/brown, white-blue/blue, white-orange/orange, white-green/green
Twisted pair shield Material Al/Mylar
Twisted pair shield Diameter mm 0.45
sheath Diameter mm 7.4
thickness mm 0.65
Color RAL7032 (gray)
Gel filled No
Carrier cable No
Spline Yes
Length marker print error % <0.5
Electrical parameters
Impedance Ohm 100
Nominal Velocity of Propagation NVP % 74
Delay skew ns/100 m <45
Asymmetry in capacitance of transmission paths to the ground pF/100 m 330
DC resistance Ohm/100 m 9.38
Resistance asymmetry % <5
Return Loss 1 MHz ≥dB 20
Return Loss 4 MHz ≥dB 23
8 MHz ≥dB 24.5
10 MHz ≥dB 25
16 MHz ≥dB 25
20 MHz ≥dB 25
25 MHz ≥dB 24.3
31.25 MHz ≥dB 23.6
62.5 MHz ≥dB 21.5
100 MHz ≥dB 20.1
200 MHz ≥dB 18
250 MHz ≥dB 17.3
300 MHz ≥dB 17.3
500 MHz ≥dB 15.2
Loss 4 MHz ≤dB 3.8
8 MHz ≤dB 5.3
10 MHz ≤dB 5.9
16 MHz ≤dB 7.5
20 MHz ≤dB 8.4
25 MHz ≤dB 9.4
31.25 MHz ≤dB 10.5
62.5 MHz ≤dB 15
100 MHz ≤dB 19.1
200 MHz ≤dB 27.6
250 MHz ≤dB 31.1
300 MHz ≤dB 34.3
500 MHz ≤dB 45.3
NEXT (near-end crosstalk) 1 MHz ≤dB 74.3
NEXT (near-end crosstalk) 4 MHz ≤dB 65.3
8 MHz ≤dB 60.8
10 MHz ≤dB 59.3
16 MHz ≤dB 56.2
20 MHz ≤dB 54.8
25 MHz ≤dB 53.3
31.25 MHz ≤dB 51.9
62.5 MHz ≤dB 47.7
100 MHz ≤dB 44.3
200 MHz ≤dB 39.8
250 MHz ≤dB 38.3
300 MHz ≤dB 37.1
500 MHz ≤dB 33.8
PSNEXT (power sum near-end crosstalk) 1 MHz ≥dB 72.3
PSNEXT (power sum near-end crosstalk) 4 MHz ≥dB 63.3
8 MHz ≥dB 58.8
10 MHz ≥dB 57.3
16 MHz ≥dB 54.2
20 MHz ≥dB 52.8
25 MHz ≥dB 51.3
31.25 MHz ≥dB 49.9
62.5 MHz ≥dB 45.4
100 MHz ≥dB 42.3
200 MHz ≥dB 37.8
250 MHz ≥dB 36.3
300 MHz ≥dB 35.1
500 MHz ≥dB 31.8
ELFEXT 1 MHz ≥dB 67.8
ELFEXT 4 MHz ≥dB 55.8
8 MHz ≥dB 49.7
10 MHz ≥dB 47.8
16 MHz ≥dB 43.7
20 MHz ≥dB 41.8
25 MHz ≥dB 39.8
31.25 MHz ≥dB 37.9
62.5 MHz ≥dB 31.9
100 MHz ≥dB 27.8
200 MHz ≥dB 21.8
250 MHz ≥dB 19.8
300 MHz ≥dB 18.5
500 MHz ≥dB 13.8
PSELFEXT (power sum far-end crosstalk) 1 MHz ≥dB 64.8
PSELFEXT (power sum far-end crosstalk) 4 MHz ≥dB 52.8
8 MHz ≥dB 46.7
10 MHz ≥dB 44.8
16 MHz ≥dB 40.7
20 MHz ≥dB 38.8
25 MHz ≥dB 36.8
31.25 MHz ≥dB 34.9
62.5 MHz ≥dB 28.9
100 MHz ≥dB 24.8
200 MHz ≥dB 18.8
250 MHz ≥dB 16.8
300 MHz ≥dB 15.3
500 MHz ≥dB 10.8
Mechanical properties
Operating temperature °C -30...+50
Installation temperature °C 0...+50
Minimum bending radius for indoor installation Diameter >8
Packaging
Spool Diameter mm 380
Spool Width mm 385
spool hole diameter mm 33