€395.73
Price | Disc. | Quantity | Validity |
---|---|---|---|
€395.73 | 0 % | from 1 piece |
Available
NETSET U/FTP Category 6A twisted pair cable is the highest quality twisted pair cable designed for professional indoor installations.
• Cable type: U/FTP
• Category 6A
• Application: interior
• Flammability class B2ca s1a,d1,a1
• Conductor diameter 0.57 mm (23 AWG)
• Roll of 500 m
• Category 6A
• Application: interior
• Flammability class B2ca s1a,d1,a1
• Conductor diameter 0.57 mm (23 AWG)
• Roll of 500 m
Details
NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables for use in construction works.
NETSET U/FTP 6A is a top quality indoor FTP CAT 6A twisted-pair cable designed for use in professional computer networks inside buildings. Shielding layers made of aluminum foil minimize crosstalk between pairs and interference with the external environment.
- highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
- parameters far exceeding the requirements for Category 6A twisted pair cables,
- preliminary quality control of materials and thorough tests of the final product,
- solid wires of 0.57 mm diameter (23 AWG),
- wire insulation made of Skin-foam-skin PE; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
- insulated wires twisted in pairs, shielded with aluminum foil,
- sheath made of LSZH material of 7.4 mm diameter,
- meter markers - length error less than 0.5%.

1 - white-blue/blue wire
2 - white-brown/brown wire
3 - white-green/green wire
4 - white-orange/orange
5 - drain wire
6 - Rip-cord
7 - aluminum shielding
8 - sheath (jacket)
2 - white-brown/brown wire
3 - white-green/green wire
4 - white-orange/orange
5 - drain wire
6 - Rip-cord
7 - aluminum shielding
8 - sheath (jacket)
The NETSET U/FTP cat. 6A E1617 twisted pair cable has been manufactured in accordance with the standards:
- General requirements for category 6A
- ISO/IEC 11801:2011 (Ed. 2.2)
- IEC 61156-5:2012 (Ed. 2.1)
- EN 50173-1:2011
- EN 50173-2:2007 A1:2010
- EN 50288-10-1:2012
- ANSI/TIA-568-C.2:2009
- Flammability standards
- IEC 60332-1-1:2015 (Ed. 1.1) / IEC 60332-1-2:2015 (Ed. 1.1)
- IEC 60754-1:2011 (Ed. 3.0) / IEC 60754-2:2011 (Ed. 2.0)
- IEC 61034-1:2013 (Ed. 3.1) / IEC 61034-2:2013 (Ed. 3.1)
- Reaction to fire
- Classification B2ca-s1a-d1-a1
- EN 50575:2014 including amendment A1:2016
- EN 60332-1-2:2004 including amendment A1:2015
- EN 13501-6:2014
The cable comes with a 15-year warranty.
The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET U/FTP Category 6A E1617 twisted pair cable is intended for use in an environment with temperature from -30oC to +50 oC. Installation temperature not lower than 0oC and not higher than +50oC. The bending radius should not be less than 8 times the outside diameter.
NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables for use in construction works.
Test results
- Return Loss
Frequency [MHz] | Result [dB] |
1 | 20 |
4 | 23 |
8 | 24.5 |
10 | 25 |
16 | 25 |
20 | 25 |
25 | 24.3 |
31.25 | 23.6 |
62.5 | 21.5 |
100 | 20.1 |
200 | 18 |
250 | 17.3 |
300 | 16.8 |
500 | 15.2 |
- Attenuation
Frequency [MHz] | Result [dB/100m] | |
1 | 2.1 | |
4 | 3.8 | |
8 | 5.3 | |
10 | 5.9 | |
16 | 7.5 | |
20 | 8.4 | |
25 | 9.4 | |
31.25 | 10.5 | |
62.5 | 15 | |
100 | 19.1 | |
200 | 27.6 | |
250 | 31.1 | |
300 | 34.3 | |
500 | 45.3 |
Frequency [MHz] | Result [dB] |
1 | 74.3 |
4 | 65.3 |
8 | 60.8 |
10 | 59.3 |
16 | 56.2 |
20 | 54.8 |
25 | 53.3 |
31.25 | 51.9 |
62.5 | 47.4 |
100 | 44.3 |
200 | 39.8 |
250 | 38.3 |
300 | 37.1 |
500 | 33.8 |
- PSNEXT
Frequency [MHz] | Result [dB] |
1 | 72.3 |
4 | 63.3 |
8 | 58.8 |
10 | 57.3 |
16 | 54.2 |
20 | 52.8 |
25 | 51.3 |
31.25 | 49.9 |
62.5 | 45.4 |
100 | 42.3 |
200 | 37.8 |
250 | 36.3 |
300 | 35.1 |
500 | 31.8 |
- ELFEXT
Frequency [MHz] | Result [dB] |
1 | 68 |
4 | 56 |
8 | 49.9 |
10 | 48 |
16 | 43.9 |
20 | 42 |
25 | 40 |
31.25 | 38.1 |
62.5 | 32.1 |
100 | 28 |
200 | 22 |
250 | 20 |
300 | 18.5 |
500 | 14 |
Frequency [MHz] | Result [dB] |
1 | 65 |
4 | 53 |
8 | 46.9 |
10 | 45 |
16 | 40.9 |
20 | 39 |
25 | 37 |
31.25 | 35.1 |
62.5 | 29.1 |
100 | 25 |
200 | 19 |
250 | 17 |
300 | 15.5 |
500 | 11 |
Specifications
Name | NETSET U/FTP cat. 6A | ||
Product type | twisted-pair cable | ||
Manufacturer | Dipol | ||
Brand | NETSET | ||
Cable type | U/FTP | ||
Applications | Indoor | ||
Category | 6A | ||
Cable length | m | 500 | |
CPR class | B2ca s1a,d1,a1 | ||
Physical properties | |||
Conductor | Material | Cooper | |
Conductor | Diameter | mm | 0.560 |
Conductor insulation | Material | PE | |
Conductor insulation | Diameter | mm | 1.33 |
Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
Twisted pair shield | Material | Al/Mylar | |
Twisted pair shield | Diameter | mm | 0.45 |
sheath | Diameter | mm | 7.4 |
thickness | mm | 0.65 | |
Color | RAL7032 (gray) | ||
Gel filled | No | ||
Carrier cable | No | ||
Spline | Yes | ||
Length marker print error | % | <0.5 | |
Electrical parameters | |||
Impedance | Ohm | 100 | |
Nominal Velocity of Propagation NVP | % | 74 | |
Delay skew | ns/100 m | <45 | |
Asymmetry in capacitance of transmission paths to the ground | pF/100 m | 330 | |
DC resistance | Ohm/100 m | 9.38 | |
Resistance asymmetry | % | <5 | |
Return Loss | 1 MHz | ≥dB | 20 |
Return Loss | 4 MHz | ≥dB | 23 |
8 MHz | ≥dB | 24.5 | |
10 MHz | ≥dB | 25 | |
16 MHz | ≥dB | 25 | |
20 MHz | ≥dB | 25 | |
25 MHz | ≥dB | 24.3 | |
31.25 MHz | ≥dB | 23.6 | |
62.5 MHz | ≥dB | 21.5 | |
100 MHz | ≥dB | 20.1 | |
200 MHz | ≥dB | 18 | |
250 MHz | ≥dB | 17.3 | |
300 MHz | ≥dB | 17.3 | |
500 MHz | ≥dB | 15.2 | |
Loss | 4 MHz | ≤dB | 3.8 |
8 MHz | ≤dB | 5.3 | |
10 MHz | ≤dB | 5.9 | |
16 MHz | ≤dB | 7.5 | |
20 MHz | ≤dB | 8.4 | |
25 MHz | ≤dB | 9.4 | |
31.25 MHz | ≤dB | 10.5 | |
62.5 MHz | ≤dB | 15 | |
100 MHz | ≤dB | 19.1 | |
200 MHz | ≤dB | 27.6 | |
250 MHz | ≤dB | 31.1 | |
300 MHz | ≤dB | 34.3 | |
500 MHz | ≤dB | 45.3 | |
NEXT (near-end crosstalk) | 1 MHz | ≤dB | 74.3 |
NEXT (near-end crosstalk) | 4 MHz | ≤dB | 65.3 |
8 MHz | ≤dB | 60.8 | |
10 MHz | ≤dB | 59.3 | |
16 MHz | ≤dB | 56.2 | |
20 MHz | ≤dB | 54.8 | |
25 MHz | ≤dB | 53.3 | |
31.25 MHz | ≤dB | 51.9 | |
62.5 MHz | ≤dB | 47.7 | |
100 MHz | ≤dB | 44.3 | |
200 MHz | ≤dB | 39.8 | |
250 MHz | ≤dB | 38.3 | |
300 MHz | ≤dB | 37.1 | |
500 MHz | ≤dB | 33.8 | |
PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 72.3 |
PSNEXT (power sum near-end crosstalk) | 4 MHz | ≥dB | 63.3 |
8 MHz | ≥dB | 58.8 | |
10 MHz | ≥dB | 57.3 | |
16 MHz | ≥dB | 54.2 | |
20 MHz | ≥dB | 52.8 | |
25 MHz | ≥dB | 51.3 | |
31.25 MHz | ≥dB | 49.9 | |
62.5 MHz | ≥dB | 45.4 | |
100 MHz | ≥dB | 42.3 | |
200 MHz | ≥dB | 37.8 | |
250 MHz | ≥dB | 36.3 | |
300 MHz | ≥dB | 35.1 | |
500 MHz | ≥dB | 31.8 | |
ELFEXT | 1 MHz | ≥dB | 67.8 |
ELFEXT | 4 MHz | ≥dB | 55.8 |
8 MHz | ≥dB | 49.7 | |
10 MHz | ≥dB | 47.8 | |
16 MHz | ≥dB | 43.7 | |
20 MHz | ≥dB | 41.8 | |
25 MHz | ≥dB | 39.8 | |
31.25 MHz | ≥dB | 37.9 | |
62.5 MHz | ≥dB | 31.9 | |
100 MHz | ≥dB | 27.8 | |
200 MHz | ≥dB | 21.8 | |
250 MHz | ≥dB | 19.8 | |
300 MHz | ≥dB | 18.5 | |
500 MHz | ≥dB | 13.8 | |
PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 64.8 |
PSELFEXT (power sum far-end crosstalk) | 4 MHz | ≥dB | 52.8 |
8 MHz | ≥dB | 46.7 | |
10 MHz | ≥dB | 44.8 | |
16 MHz | ≥dB | 40.7 | |
20 MHz | ≥dB | 38.8 | |
25 MHz | ≥dB | 36.8 | |
31.25 MHz | ≥dB | 34.9 | |
62.5 MHz | ≥dB | 28.9 | |
100 MHz | ≥dB | 24.8 | |
200 MHz | ≥dB | 18.8 | |
250 MHz | ≥dB | 16.8 | |
300 MHz | ≥dB | 15.3 | |
500 MHz | ≥dB | 10.8 | |
Mechanical properties | |||
Operating temperature | °C | -30...+50 | |
Installation temperature | °C | 0...+50 | |
Minimum bending radius for indoor installation | Diameter | >8 | |
Packaging | |||
Spool | Diameter | mm | 380 |
Spool | Width | mm | 385 |
spool hole diameter | mm | 33 |