€397.07
| Price | Disc. | Quantity | Validity |
|---|---|---|---|
| €397.07 | 0 % | from 1 piece |
Available
The NETSET U/UTP cat. 6A is the finest-quality twisted pair cable designed for professional data transmission systems inside buildings.
• Cable type: U/UTP
• Category 6A
• Uses: indoors
• Fire class B2ca s1a, d1, a1
• Conductor diameter 0.565 mm
• 500-metre reel
• Category 6A
• Uses: indoors
• Fire class B2ca s1a, d1, a1
• Conductor diameter 0.565 mm
• 500-metre reel
Details
NETSET U/FTP 6A is a top quality indoor FTP CAT 6A twisted-pair cable designed for use in professional computer networks inside buildings. Shielding layers made of aluminum foil minimize crosstalk between pairs and interference with the external environment.
- top quality materials, made to tight specifications, proven with a 15-year quality guarantee
- parameters by far exceeding the requirements of category 6A
- pre-production quality control of raw materials and post-production quality control of the finished product
- meter marker
- single stranded copper conductors with a diameter of Ø 0.565 mm (23 by AWG)
- conductor insulation made of polyethylene Skin-foam-skin PE, conductor insulation colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue
- insulated conductors twisted in pairs
- cable sheath made of LSZH, outer diameter Ø 7.5 mm
- error in printing meter max. 0.5%
The NETSET U/UTP cat. 6A E1618 twisted pair cable has been manufactured in accordance with the standards:
- General requirements for category 6A
- ISO/IEC 11801:2011 (Ed. 2.2)
- IEC 61156-5:2012 (Ed. 2.1)
- EN 50173-1:2011
- EN 50173-2:2007 A1:2010
- EN 50288-10-1:2012
- ANSI/TIA-568-C.2:2009
- Flammability standards
- IEC 60332-1-1:2015 (Ed. 1.1) / IEC 60332-1-2:2015 (Ed. 1.1)
- IEC 60754-1:2011 (Ed. 3.0) / IEC 60754-2:2011 (Ed. 2.0)
- IEC 61034-1:2013 (Ed. 3.1) / IEC 61034-2:2013 (Ed. 3.1)
- Reaction to fire
- Classification B2ca-s1a-d1-a1
- EN 50575:2014 including amendment A1:2016
- EN 60332-1-2:2004 including amendment A1:2015
- EN 13501-6:2014
The cable comes with a 15-year warranty
The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET U/UTP Category 6A E1617 twisted pair cable is intended for use in an environment with temperature from -30oC to 50 oC. Installation temperature not lower than 0oC and not higher than 50oC. The bending radius should not be less than 8 times the outside diameter.
NETSET brand cables are compliant with the directive CPR and comply with the European standard EN 50575, which specifies fire performance requirements, test methods and evaluation of cables as building materials.
Test results
- Return Loss
| Frequency [MHz] | Result [dB] |
| 1 | 20 |
| 4 | 23 |
| 8 | 24.5 |
| 10 | 25 |
| 16 | 25 |
| 20 | 25 |
| 25 | 24.3 |
| 31.25 | 23.6 |
| 62.5 | 21.5 |
| 100 | 20.1 |
| 200 | 18 |
| 250 | 17.3 |
| 300 | 16.8 |
| 500 | 15.2 |

The return loss graph of the cable compared with the EN 50173 standard.
- Attenuation
| Frequency [MHz] | Result [dB/100m] | |
| 1 | 2.1 | |
| 4 | 3.8 | |
| 8 | 5.3 | |
| 10 | 5.9 | |
| 16 | 7.5 | |
| 20 | 8.4 | |
| 25 | 9.4 | |
| 31.25 | 10.5 | |
| 62.5 | 15 | |
| 100 | 19.1 | |
| 200 | 27.6 | |
| 250 | 31.1 | |
| 300 | 34.3 | |
| 500 | 45.3 |
- NEXT
| Frequency [MHz] | Result [dB] |
| 1 | 74.3 |
| 4 | 65.3 |
| 8 | 60.8 |
| 10 | 59.3 |
| 16 | 56.2 |
| 20 | 54.8 |
| 25 | 53.3 |
| 31.25 | 51.9 |
| 62.5 | 47.4 |
| 100 | 44.3 |
| 200 | 39.8 |
| 250 | 38.3 |
| 300 | 37.1 |
| 500 | 33.8 |

The NEXT (near end crosstalk) graph of the cable compared with the EN 50173 standard.
- PSNEXT
| Frequency [MHz] | Result [dB] |
| 1 | 72.3 |
| 4 | 63.3 |
| 8 | 58.8 |
| 10 | 57.3 |
| 16 | 54.2 |
| 20 | 52.8 |
| 25 | 51.3 |
| 31.25 | 49.9 |
| 62.5 | 45.4 |
| 100 | 42.3 |
| 200 | 37.8 |
| 250 | 36.3 |
| 300 | 35.1 |
| 500 | 31.8 |

The PSNEXT (power sum near end crosstalk) graph of the cable compared with the EN 50173 standard.
- ELFEXT
| Frequency [MHz] | Result [dB] |
| 1 | 68 |
| 4 | 56 |
| 8 | 49.9 |
| 10 | 48 |
| 16 | 43.9 |
| 20 | 42 |
| 25 | 40 |
| 31.25 | 38.1 |
| 62.5 | 32.1 |
| 100 | 28 |
| 200 | 22 |
| 250 | 20 |
| 300 | 18.5 |
| 500 | 14 |

The ELFEXT graph of the cable compared with the EN 50173 standard.
- PSELFEXT
| Frequency [MHz] | Result [dB] |
| 1 | 65 |
| 4 | 53 |
| 8 | 46.9 |
| 10 | 45 |
| 16 | 40.9 |
| 20 | 39 |
| 25 | 37 |
| 31.25 | 35.1 |
| 62.5 | 29.1 |
| 100 | 25 |
| 200 | 19 |
| 250 | 17 |
| 300 | 15.5 |
| 500 | 11 |

The PSELFEXT graph of the cable compared with the EN 50173 standard.
Specifications
| Name | NETSET U/UTP kat.6A B2ca | ||
| Product type | twisted-pair cable | ||
| Manufacturer | DIPOL | ||
| Brand | NETSET | ||
| Cable type | U/UTP | ||
| Applications | Indoor | ||
| Category | 6A | ||
| Cable length | m | 500 | |
| CPR class | B2ca s1a,d1,a | ||
| Physical properties | |||
| Conductor | Material | Cooper | |
| Diameter | mm | 0.565 | |
| Conductor insulation | Material | PE | |
| Diameter | mm | 1.12 | |
| Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
| sheath | Diameter | mm | 7.5 |
| thickness | mm | 0.65 | |
| Color | RAL7032 (gray) | ||
| Gel filled | No | ||
| Carrier cable | No | ||
| Spline | Yes | ||
| Length marker print error | % | <0.5 | |
| Electrical parameters | |||
| Impedance | Ohm | 100 | |
| Nominal Velocity of Propagation NVP | % | 74 | |
| Delay skew | ns/100 m | <45 | |
| Asymmetry in capacitance of transmission paths to the ground | pF/100 m | 330 | |
| DC resistance | Ohm/100 m | 9.38 | |
| Resistance asymmetry | % | <5 | |
| Return Loss | 1 MHz | ≥dB | 20 |
| 4 MHz | ≥dB | 23 | |
| 8 MHz | ≥dB | 24.5 | |
| 10 MHz | ≥dB | 25 | |
| 16 MHz | ≥dB | 25 | |
| 20 MHz | ≥dB | 25 | |
| 25 MHz | ≥dB | 24.3 | |
| 31.25 MHz | ≥dB | 23.6 | |
| 62.5 MHz | ≥dB | 21.5 | |
| 100 MHz | ≥dB | 20.1 | |
| 200 MHz | ≥dB | 18 | |
| 250 MHz | ≥dB | 17.3 | |
| 300 MHz | ≥dB | 17.3 | |
| 500 MHz | ≥dB | 15.2 | |
| Loss | 4 MHz | ≤dB | 3.8 |
| 8 MHz | ≤dB | 5.3 | |
| 10 MHz | ≤dB | 5.9 | |
| 16 MHz | ≤dB | 7.5 | |
| 20 MHz | ≤dB | 8.4 | |
| 25 MHz | ≤dB | 9.4 | |
| 31.25 MHz | ≤dB | 10.5 | |
| 62.5 MHz | ≤dB | 15 | |
| 100 MHz | ≤dB | 19.1 | |
| 200 MHz | ≤dB | 27.6 | |
| 250 MHz | ≤dB | 31.1 | |
| 300 MHz | ≤dB | 34.3 | |
| 500 MHz | ≤dB | 45.3 | |
| NEXT (near-end crosstalk) | 1 MHz | ≤dB | 74.3 |
| 4 MHz | ≤dB | 65.3 | |
| 8 MHz | ≤dB | 60.8 | |
| 10 MHz | ≤dB | 59.3 | |
| 16 MHz | ≤dB | 56.2 | |
| 20 MHz | ≤dB | 54.8 | |
| 25 MHz | ≤dB | 53.3 | |
| 31.25 MHz | ≤dB | 51.9 | |
| 62.5 MHz | ≤dB | 47.7 | |
| 100 MHz | ≤dB | 44.3 | |
| 200 MHz | ≤dB | 39.8 | |
| 250 MHz | ≤dB | 38.3 | |
| 300 MHz | ≤dB | 37.1 | |
| 500 MHz | ≤dB | 33.8 | |
| PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 72.3 |
| 4 MHz | ≥dB | 63.3 | |
| 8 MHz | ≥dB | 58.8 | |
| 10 MHz | ≥dB | 57.3 | |
| 16 MHz | ≥dB | 54.2 | |
| 20 MHz | ≥dB | 52.8 | |
| 25 MHz | ≥dB | 51.3 | |
| 31.25 MHz | ≥dB | 49.9 | |
| 62.5 MHz | ≥dB | 45.4 | |
| 100 MHz | ≥dB | 42.3 | |
| 200 MHz | ≥dB | 37.8 | |
| 250 MHz | ≥dB | 36.3 | |
| 300 MHz | ≥dB | 35.1 | |
| 500 MHz | ≥dB | 31.8 | |
| ELFEXT | 1 MHz | ≥dB | 67.8 |
| 4 MHz | ≥dB | 55.8 | |
| 8 MHz | ≥dB | 49.7 | |
| 10 MHz | ≥dB | 47.8 | |
| 16 MHz | ≥dB | 43.7 | |
| 20 MHz | ≥dB | 41.8 | |
| 25 MHz | ≥dB | 39.8 | |
| 31.25 MHz | ≥dB | 37.9 | |
| 62.5 MHz | ≥dB | 31.9 | |
| 100 MHz | ≥dB | 27.8 | |
| 200 MHz | ≥dB | 21.8 | |
| 250 MHz | ≥dB | 19.8 | |
| 300 MHz | ≥dB | 18.5 | |
| 500 MHz | ≥dB | 13.8 | |
| PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 64.8 |
| 4 MHz | ≥dB | 52.8 | |
| 8 MHz | ≥dB | 46.7 | |
| 10 MHz | ≥dB | 44.8 | |
| 16 MHz | ≥dB | 40.7 | |
| 20 MHz | ≥dB | 38.8 | |
| 25 MHz | ≥dB | 36.8 | |
| 31.25 MHz | ≥dB | 34.9 | |
| 62.5 MHz | ≥dB | 28.9 | |
| 100 MHz | ≥dB | 24.8 | |
| 200 MHz | ≥dB | 18.8 | |
| 250 MHz | ≥dB | 16.8 | |
| 300 MHz | ≥dB | 15.3 | |
| 500 MHz | ≥dB | 10.8 | |
| Mechanical properties | |||
| Operating temperature | °C | -30...+50 | |
| Installation temperature | °C | 0...+50 | |
| Minimum bending radius for indoor installation | Diameter | >8 | |
| Packaging | |||
| Spool | Diameter | mm | 380 |
| Width | mm | 385 | |