Coaxial Cable 50 ohm: Tri-Lan 240 PE Fca [1m]
Code: E1171_1
The cable guarantees not only efficient power transmission but also ensures savings on installation cost, in the process of migration from 2.4GHz to 5GHz band (it can work in both bands, so the cabling will not have to be replaced).
The sheath of the cable is made of PE (UV-resistant), so Tri-Lan 240 can be used outdoors.
Cable structure.
Main features
- low loss (as far as 20% lower than of H155)
- perfect matching (30 dB at 2.4GHz)
- high screening efficiency (90dB at 2.4GHz)
TRILAN cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
Modern low-loss RF cable up to 6 GHz.
The item E1171_1 - for retail sale of required number of meters
Declaration of RoHS compliance.
Tri-Lan 240 - low-loss cable.
Specifications
| Name | Tri-Lan 240 | ||
| Code | E1171 | ||
| tolerance | |||
| Copper core | |||
| Diameter | mm | 1.4 | +/-0.02 |
| Mechanically foamed dielectric | |||
| Outer diameter | mm | 3.8 | +/- 0.05 |
| Shielding | |||
| Al foil/Polyester/Al foil: | um | 12/15/12 | |
| Covering factor | % | 100 | |
| CuSn braid: | 16x7x0.12 | ||
| Covering factor | % | 80 | |
| Outer diameter | mm | 4.45 | |
| Sheath | |||
| Material | PE | ||
| Outer diameter | 6.10 | +/-0.10 | |
| Color | black | ||
| Electrical parameters | |||
| Impedance | ohm | 50 | +/-2 |
| Capacitance | pF/m | 83 | |
| Wave reduction factor | % | 81 | |
| Screening efficiency | dB | >90 | |
| Resistance of the core | ohm/km | 11.2 | |
| Resistance of the shielding | ohm/km | 12.4 | |
| Other parameters | |||
| Minimum bending radius | mm | 30/60 | |
| Weight | kg/km | 47 | |
| Working temperature | ºC | -40 to +70 | |
With this cable there can be used all connectors suitable for H-155 cable (working up to 2.4 GHz).
For 5GHz band we recommend the connectors working up to 6 GHz: N-plug
Maximum transmitted power
Frequency [MHz] | Power [kW] |
30 | 1.41 |
50 | 1.09 |
150 | 0.62 |
220 | 0.51 |
450 | 0.35 |
900 | 0.24 |
1500 | 0.19 |
1800 | 0.17 |
| 2000 | 0.16 |
| 2500 | 0.14 |
| 5800 | 0.09 |
Cable loss at 20C
| Frequency [MHz] | Attenuation [dB/100m] |
| 30 | 4.2 |
| 50 | 5.4 |
| 150 | 9.2 |
| 220 | 11.2 |
| 450 | 16.2 |
| 900 | 23.3 |
| 1500 | 30.7 |
| 1800 | 33.9 |
| 2000 | 35.9 |
| 2500 | 40.6 |
| 5800 | 65.2 |

Loss versus frequency - 10m cable segment (measurements performed in CLBT).

Matching characteristics (measurements performed in CLBT).