Coaxial Cable (50 ohm): Tri-Lan 400 WLL PE Fca [100m]

Code: E1173_100
€316.59
Price Disc. Quantity Validity
€316.59 0 % from 1 piece
Available
The cable may be used in WLANs working at 2.4 GHz and 5 GHz. Application of this cable in 2.4 GHz system will allow to migrate the system in the future to 5 GHz, without a need of changing cabling.

Warranty

5-year warranty.

Support

Details

The cable may be used in WLANs working at 2.4 GHz and 5 GHz. Application of this cable in 2.4 GHz system will allow to migrate the system in the future to 5 GHz, without a need of changing cabling.
Modern low loss RF cable up to 6 GHz.
Cable structure.
Main features
  • low loss (lower than in the case of popular H-1000),
  • perfect matching,
  • high screening efficiency (90 dB at 2.4 GHz).
TRILAN cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
The cable is sold in the quantities:
100m E1173_100,
and required number of meters E1173_1.

RoHS compliance declaration.
The sheath of the cable is made of PE (Borealis LE 8707 - from renown producer), so the cable is perfect for outdoor applications.
The cable can be used with any connector suitable for H-1000 (working at 2.4 GHz).
For 5 GHz band there should be used adequate connectors, e.g. N.
Maximum transmitted power
Frequency [MHz] Power [kW]]
30 3.36
50 2.59
150 1.47
220 1.2
450 0.82
900 0.57
1500 0.43
1800 0.39
2000 0.36
2500 0.32
5800 0.20
Cable loss at 20C
Frequency [MHz] Attenuation [dB/100m]
30 2.3
50 3.0
150 4.9
220 6.0
450 8.7
900 12.8
1500 17.0
1800 18.8
2000 20.0
2500 22.7
5800 37.6
Price for 100m

Specifications

Product type Coaxial cable
type Tri-LAN 400
Brand Tri-Lan
Applications Outdoor
Cable length m 100
CPR class FCA
Gel-filled cable No
Physical properties
Impedance Ohm 50
Conductor Material Coper
Conductor Diameter mm 2.7
Dielectric foaming Physical
Dielectric Diameter mm 7.2
shield
No. of plies 1
First foil bonded to dielectric No
First foil Material Al/Polyester foil
Dimensions μm 25/12
Braid Material CuSn
Braid wire diameter mm 24 × 7 × 0,15
braid coverage % 83
sheath Material PE
sheath Diameter mm 10.3
Color RAL9005 (black)
Electrical parameters
Maximum transmitted power 30 MHz kW 3.36
Maximum transmitted power 50 MHz kW 2.59
150 MHz kW 1.47
220 MHz kW 1.2
450 MHz kW 0.82
900 MHz kW 0.57
1500 MHz kW 0.43
1800 MHz kW 0.39
2000 MHz kW 0.36
2500 MHz kW 0.32
5800 MHz kW 0.2
Cable attenuation 30 MHz dB/100 m 2.3
Cable attenuation 50 MHz dB/100 m 3
150 MHz dB/100 m 4.9
220 MHz dB/100 m 6
450 MHz dB/100 m 8.7
900 MHz dB/100 m 12.8
1500 MHz dB/100 m 17
1800 MHz dB/100 m 18.8
2000 MHz dB/100 m 20
2500 MHz dB/100 m 22.7
5800 MHz dB/100 m 37.6
Resistance at 20°C core Ω/km 3.1
Resistance at 20°C braid Ω/km 5.8
capacity pF/m 80
Wave reduction factor % 83
Mechanical properties
Operating temperature °C -40...+70
Minimum bending radius mm 50/100
Weight kg/km 149.2