This product is no longer available
Replacements
Support
Details
High-class coaxial cable Triset-113 HF E1019_500 is dedicated for use in community and cable TV installations to link subnetworks. The cable is made in HF (halogen free) technology so it is also suitable for building installations in schools and hospitals. In the case of fire, the cable is flame retardant and emits little smoke, the emitted gases are not corrosive.
Key features
- complies with A-class requirements
- passed IEC 68-2-3 Steady State Damp Heat test
- 1.13 mm copper core
- low loss
- perfect matching,
- high screening efficiency - A+ class in the vast majority of the transmission range
- 81% braid coverage
- 5-year warranty
TRISET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
TRISET-113 HF E1019 75 ohm coaxial cable has been examined by L.S. Fire Testing Institute Srl notified body (NB 2479) and got Dca-s1a, d2, a1 classification according to EN 13501-6 (reaction to fire).
TRISET-113 cables comply with the EN50117 standard and A-class requirements in the whole 5...3000 MHz transmission frequency range.
RoHS compliance declaration.
TRISET-113 HF is compliant with the following standards:
- IEC 60332-1, EN 60332-1 - tests on electric and optical fiber cables under fire condition
- IEC 60754-1, EN 50267-2-1 - halogen content test
- IEC 60754-2, EN 50267-2-2 - determination of acidity of gases evolved during combustion
- IEC 61034-2, EN 61034-2 - method of test for the measurement of the density of smoke emitted from electric cables burning under the defined conditions of the test
Triset-113 E1019_500 has a braid coverage of 81%, which is the basis for high screening efficiency.
The high-quality, double shielded coaxial cable of RG6 category has the inner conductor made of copper wire with a diameter of 1.13 mm, which ensures low loss and durability. The copper wire core does not corrode and the cable is not stiff.
Thanks to high quality and very good parameters, the cable enjoys great popularity among many installers. An optimum flexibility of the jacket allows for easy installation of the cable in cable ducts and installation boxes.
The cable is manufactured under strict technological discipline, with tight tolerances.
In order to secure the minimum bend radius, flush mounted installations should be done with the use of protective tubes.
Screening efficiency of TRISET-113 cable in the 30-3000 MHz range
and the requirements for A class
Transfer impedance of TRISET-113 cable in 5-30 MHz range
and the requirements for A class
Insertion loss in the 5-2400 MHz frequency range
Return loss in the 5-2400 MHz frequency range
Signal propagation velocity in the 5-2400 MHz frequency range
The increase of attenuation after the accelerated aging test (IEC68-2-3) is below 5%
Coaxial cables undergo a natural aging process which results in increasing attenuation. The quality of a cable in the process of accelerated aging is tested according to IEC68-2-3 standard. The Triset cable passed the test and its quality is guaranteed by a 5-year warranty.
Specifications
Name | TRISET 113 | ||
Code | E1019 | ||
tolerance | |||
Copper core | |||
Diameter | mm | 1,13 | ± 0,03 |
Physically foamed dielectric | |||
Thickness | mm | 1,83 | ± 0,05 |
Diameter | mm | 4,80 | ± 0,1 |
Ovality (non-circularity) | ± 2% | ||
Al/PET/Al foil 30/12/30 µm adhered to the dielectric | |||
Width | mm | 18 | ± 0,3 |
Overlap | mm | >3 | ± 0,5 |
Total thickness | µm | 75 | ± 3 |
Braid | |||
Material | Aluminum | ||
Wire diameter | mm | 0,12 | ± 0,01 |
Number of wires | pc | 24 x 6 | |
Winding angle | degree | 19,34 | |
Braid coverage | % | 81 | |
Jacket | |||
Material | HF | ||
Thickness | mm | 0,8 | ± 0,1 |
Diameter | mm | 6,8 | +0,20/-0,05 |
Color | White (RAL 9010) | ||
Electrical parameters | |||
Resistance (20°C) | Ω/km | 16,85 | ± 0,5 |
Capacitance | pF/m | 52 | ± 1,5 |
Dielectric resistance | MΩ/km | 2000 | ± 3% |
Impedance | Ω | 75 | ± 3 |
Wave reduction factor | % | 84 | ± 1 |
Mechanical parameters | |||
Operating temperature range | °C | -30...+70 | |
Installation temperature range | °C | -5...+40 | |
Minimum bending radius | mm | 35 (single) 70 (repeated) |
According to EN50117 norm, there are the next classes of coaxial cables, depending on screening efficiency: C, B, A, A+, A++.
Taking into consideration cables for antenna systems, Triset 113 has the highest screening efficiency, between A and A+.
Classes of screening efficiency
Class\freq. range | 5-30 MHz [mΩ/m] | 30-1000 MHz [dB] | 1-2 GHz [dB] | 2-3 GHz [dB] |
C | 50 | 75 | 65 | 55 |
B | 15 | 75 | 65 | 55 |
A | 5 | 85 | 75 | 65 |
A+ | 2.5 | 95 | 85 | 75 |
A++ | 0.9 | 105 | 95 | 85 |
Price for 500m
Specifications
Wymagania | Charakterystyka Triset-113 | |
Kategoria RG-6 lub wyższa | Kable z rodziny Triset-113 są kablami kategorii RG-6 o podwyższonych parametrach |
|
Podwójny ekran: folia aluminiowa + oplot o gęstości ≥ 77% |
Podwójny ekran: folia aluminiowa + oplot 81% |
|
Miedziana żyła wewnętrzna o średnicy nie mniejszej niż jeden milimetr. |
Żyła miedziana o średnicy 1,13mm | |
Klasa A | Skuteczność ekranowania 0,03...1 GHz ≥ 85 dB 1...2 GHz ≥ 75 dB 2...3 GHz ≥ 65 dB |
Skuteczność ekranowania 0,03...1 GHz ≥ 90 dB 1...2 GHz ≥ 90 dB 2...3 GHz ≥ 85 dB |
Impedancja sprzężeniowa < 5 mΩ/m | Impedancja sprzężeniowa < 4,6 mΩ/m |