High-quality TriSAT B2CA coaxial cable dedicated for the construction of RF/SAT systems. Cable with LSZH-FR+ sheath (halogen-free insulation).
• Conforms to Class A+ standard
• Complies with the requirements of the construction legislation
• Fire reaction class in accordance with CPR - B2ca-s1a,d1,a1
• Cable in LSZH-FR+ sheath • Copper core 1.00 mm
• Low attenuation
• Excellent fit
• High shielding efficiency
• 78% braid coverage
• 5-year warranty
• 500 m on the reel made of ABS packed into carton box
• Complies with the requirements of the construction legislation
• Fire reaction class in accordance with CPR - B2ca-s1a,d1,a1
• Cable in LSZH-FR+ sheath • Copper core 1.00 mm
• Low attenuation
• Excellent fit
• High shielding efficiency
• 78% braid coverage
• 5-year warranty
• 500 m on the reel made of ABS packed into carton box
Details
Quality coaxial cable TRISET B2CA E1022_500 is suitable for RF/SAT antenna systems in commercial buildings. Cable with LSZH-FR+, halogen-free insulation used where increased safety levels are required in the event of a fire (schools, hospitals etc.). In the event of a fire, the cable does not spread flame, smoke emission is very low and the released gases are not corrosive.
It has an inner cooper conductor with a diameter of 1.00 mm and triple shield (Al/PET/Al+Sur foil (first) bonded to the dielectric + 78% density braid + Al/PET foil (second) boded to the sheath).
Key features:
- conforms to Class A+ standard
- complies with the requirements of the construction legislation
- fire reaction class in accordance with CPR - B2ca-s1a,d1,a1
- cable in LSZH-FR+ sheath
- copper core 1.00 mm
- low attenuation
- excellent fit
- high shielding efficiency
- 78% braid coverage
- 5-year warranty
- 500 m on the reel made of ABS packed into carton box
The requirements for using cables with a specific reaction to fire class in a given type of building should be based on a risk analysis made by the installation designer or other national formal and legal documents. The CPR Directive does not impose on the EU Member States the requirements for types of buildings and associated cables with specific fire reaction classes. The reaction to fire class of cables and other conductors installed within evacuation routes should not be less than B2ca-s1b, d1, a1.
- High-rise buildings (WW) with a height of more than 55 m above ground level
- High-rise buildings (W) with a height of more than 25 m to 55 m above ground level or residential buildings with the number of floors above ground level from 9 to 18 inclusive
- Buildings in human risk category ZL I with rooms intended for simultaneous presence of more than 50 people who are not permanent users, and not intended primarily for use by people with reduced mobility
- Buildings in human risk category ZL II – intended primarily for use by people with reduced mobility, such as hospitals, nurseries, kindergardens, nursing homes
- Buildings in human risk category ZL III – commercial buildings not classified unser ZL I and ZL II
- Buildings in human risk category ZL IV – residential
- Buildings in human risk category ZL V – collective residence not classified under ZL I and ZL II
- PM and IN buildings (production buildings, warehouses, livestock etc.).
For more on cable fire resistance classes, read The CPR Directive - the new cable order
TRISAT cables are compliant with Construction Products Regulation (CPR) and EN 50575 standard that specifies reaction to fire performance requirements, test and assessment methods for cables used as building materials.
The 75 ohm TriSAT B2CA E1022 coaxial cable has been tested at the notified body L.S. Fire Testing Institute Srl with a number 2479 and has been awarded B2ca-s1a,d1,a1 reaction to fire class.
TriSAT B2CA complies with the EN50117 standard and A+ class requirements in the whole 5-3000 MHz transmission frequency range.
TriSAT B2CA complies with the following standards:
- EN 60332-1-2 – test methods for reaction to fire of cables.
- EN 50399 – heat release and smoke production measurement on cables during flame spread.
- EN 60754-1/2 – corrosivity of gases evolved during the combustion.
- EN 61034-2 – evaluation of formed smoke density.
The value of the cable's braid coverage (78%) remains in compliance with the requirements of the Ministry of Transport, Construction and Maritime Economy's regulation on the technical conditions to be met by buildings and their location.
High quality, triple shielded RG6 coaxial cable has an inner conductor made of +1.00 mm diameter copper wire+++, which ensures very low insertion loss. The core dose not corrode, and the cable is not stiff.
Optimum flexibility of the sheath allows for easy cable installation in shafts, as well as installation or junction boxes.
The cable is manufactured under strict quality standards, with tight tolerances.
In order to secure the minimum bend radius, flush mounted installations should be done with the use of protective conduits.
Screening efficiency TriSAT B2CA in 30-3000 MHz band
and requirements for the A+ class.
Coupling impedance in 5-30 MHz band
and requirements for the A+ class.
Insertion loss in the 5-2400 MHz frequency range
Return loss in 5-2400 MHz range
Input impedance characteristic in 5-2400 Mhz range
Matching impedance
According to the EN50117 standard, coaxial cables are divided into the following classes, depending on their screening efficiency: C, B, A, A+, A++.
Classes of screening efficiency
Class\freq. range | 5-30 MHz [mOhm/m] | 30-1000 MHz [dB] | 1-2 GHz [dB] | 2-3 GHz [dB] |
C | 50 | 75 | 65 | 55 |
B | 15 | 75 | 65 | 55 |
A | 5 | 85 | 75 | 65 |
A+ | 2.5 | 95 | 85 | 75 |
A++ | 0.9 | 105 | 95 | 85 |
Price for 500m
Specifications
Product type | Coaxial cable | ||
type | TriSAT B2CA | ||
Brand | TriSAT | ||
Cable length | m | 500 | |
Applications | Indoor | ||
Cable class | RG-6 | ||
Compliance with relevant national legislation | Yes | ||
CPR class | B2ca | ||
Gel-filled cable | No | ||
Physical properties | |||
Impedance | Ohm | 75 | |
Screening efficiency class | A+ | ||
Transfer impedance TI | mΩ/m | <0.9 | |
Conductor | Material | Coper | |
Diameter | mm | 1,00 | |
Dielectric | foaming | Physical | |
Diameter | mm | 4,6 | |
shield | |||
No. of plies | 3 | ||
First foil | bonded to dielectric | Yes | |
Material | Al/PET/Al+Sur | ||
Dimensions | μm | 18 × 12/15/12 | |
total thickness | μm | 80 | |
Braid | Material | Tin-plated cooper | |
wire diameter | mm | 0,1 | |
no. of wires | pcs. | 16 × 10 | |
braid coverage | % | 78 | |
Second foil | bonded to sheath | Yes | |
Material | Al/PET | ||
ply thickness | μm | 20 × 30/19 | |
total thickness | μm | 27 | |
sheath | Material | LSZH-FR+ | |
Diameter | mm | 6,9 | |
Color | White (RAL 9010) | ||
Electrical parameters | |||
capacity | pF/m | 54 | |
Wave reduction factor | % | 82 | |
Mechanical properties | |||
Operating temperature | °C | -25...+70 | |
Installation temperature | °C | -5...+40 | |
Minimum bending radius | mm | 35 (single) 70 (repeated) | |
Weight | kg/km | 56,20 | |
Packaging | |||
Cardboard box | Dimensions | cm | 39 × 39 × 33 |
Spool | Width | mm | 380 |
spool hole diameter | mm | 145 | |
Cable length | m | 500 |