Coaxial Cable (75 ohm): Triset-113 HF 1.13/4.8/6.8 [100m]
Code: E1019_100
This product is no longer available
This cable is compliant with the following standards:
- EN 50267-2-2:1998 - (NC - Non Corrosive) - no emission of corrosive fumes - laboratory test no. 0271B/4/2008
- EN 50268-2:1999 - (LS - Low Smoke) - low smoke emission - laboratory test no. 0271B/2/2008
- EN 50267-2-1:1998, EN 50267-1:1998 - (OH - Zero Halogen) - no emission of halogen - laboratory test no. 0271B/5/2008
High-class coaxial cable from TRISET line. For use in community and cable TV installations to link subnetworks. The cable is made in HF (halogen free) technology - in case of a fire it does not give off toxic fumes. That makes it suitable for building installations also in schools and hospitals.

The TRISET family of coaxial cables gained the Product of the Year award in "Accessories" category at SatKrak 2007 exhibition.
Main features:
- low loss,
- perfect matching,
- high screening efficiency,
- HF (halogen free).
Declaration of RoHS compliance.
Screening efficiency above 100 dB allows parallel arrangement of many cables, which is indispensable in large multiswitch installations. The core of the TRISET-113 HF (diam. of 1.13 mm) is made of copper, guarantying low loss, durability (practically no corrosion), and satisfactory flexibility. The cable is suitable for building very extensive antenna and cable TV installations. Strict technological discipline ensures small variation of parameters.
In order to secure the minimum bend radius, flush mounted installations should be done with the use of protective tubes.
Specifications
| Name | TRISET-113 HF | ||
| Code | E1019 | ||
| | tolerance | ||
Copper core | |||
Diameter | mm | 1.13 | +/- 0.03 |
Mechanically foamed HF dielectric | |||
| Thickness | mm | 1.83 | +/-0.05 |
| Diameter | mm | 4.8 | +/-0.1 |
| Ovality | | +/-2 % | |
| Aluminum foil/Pet/Aluminum foil 9+23+9 um | |||
| Width | mm | 18 | +/-0.3 |
| Tuck | mm | >3 | +/-0.5 |
| Thickness | um | 46 | +/-3 |
| Braid | |||
| Material | Aluminum | ||
| Diameter of wires | mm | 0.12 | +/-0.01 |
| Number of wires | pc | 24 x 7 | |
| Winding angle | deg | 23 | |
| Sheath | |||
| Material | PVC HF | ||
| Thickness | mm | 0.8 | +/-0.1 |
| Outer diameter | mm | 6.8 | +0.20/-0.05 |
| Color | white | | |
| General and electrical parameters | |||
| Operating temperature | °C | -30..+70 | |
| Min bending radius | mm | 35/70 | one-time/rep. |
| Resistance at 20°C | ohm/km | 16.85 | +/-0.5 |
| Capacitance | pF/m | 52 | +/-1.5 |
| Resistance of dielectric | Mohm/km | 2000 | +/-3 % |
| Impedance | ohm | 75 | +/-3 |
| Wave reduction factor | % | 84 | +/-1 |
Attenuation
Frequency [MHz] | Theoretical attenuation [dB/100m] | Measured attenuation [dB/100m] |
47 | 4.2 | 4.5 |
88 | 5.4 | 5.8 |
174 | 6.8 | 8.0 |
230 | 8.5 | 9.2 |
470 | 12.7 | 13.2 |
862 | 17.3 | 18.1 |
950 | 18.3 | 20.1 |
2150 | 28.6 | 27.7 |
2400 | 30.5 | 30.8 |
Return loss
Frequency | MHz | 5-470 | 470-862 | 862-2150 | 2150-2400 |
Theoretical | dB | >=26 | >=23 | >=20 | >=18 |
Measured | dB | 26.9 | 24 | 21 | 19 |
Shielding efficiency
Frequency | MHz | 30-2400 |
Screening factor | dB | >=100 |
According to EN50117 norm, coaxial cables are classified into C, B, A, A+, A++ groups.
Triset 113 HF features the best screening efficiency among distribution cables available on the market ( with parameters placing it between A+ and A++).
Classification of screening efficiency
Class | 30-1000 MHz | 2-3 GHz |
C | 75 | 55 |
B | 75 | 55 |
A | 85 | 65 |
A+ | 95 | 75 |
A++ | 105 | 85 |

Characteristics of the TRISET-113 HF cable. BLUE: attenuation, RED: impedance matching.
F connector E80274 Platinum crimping on Triset 113 coaxial cable
Price for 100m
This product is no longer available
Coaxial Cable (75 ohm): Triset-113 HF 1.13/4.8/6.8 [100m]
Code: E1019_100



![Coaxial Cable (75 ohm): Triset-113 HF 1.13/4.8/6.8 [100m]](https://static.dipol.com.pl/images/en/pict/e1019_100.jpg)
![Coaxial Cable (75 ohm): Triset-113 HF 1.13/4.8/6.8 [100m]](https://static.dipol.com.pl/images/en/pict/e1019++++.jpg)