TRISET-11 PE (outdoor) double-shielded coaxial cable type RG11 with the internal conductor made of copper wire with a diameter 1.65 mm.
• Bus cable
• PE sheath outer cable
• Resistant to UV radiation
• Gel to impede the spread of moisture inside the cable
• Shielding class: A
• Copper core: 1.63 mm
• 86% aluminium braid
• Double screen: foil/sheath
• CPR class: Fca
• 100 metres
• PE sheath outer cable
• Resistant to UV radiation
• Gel to impede the spread of moisture inside the cable
• Shielding class: A
• Copper core: 1.63 mm
• 86% aluminium braid
• Double screen: foil/sheath
• CPR class: Fca
• 100 metres
Details
High-class coaxial cable from TRISET line. For use in community antenna installations and cable TV, especially for linking subnetworks. Due to PE sheath (polyethylene - UV resistant), it is suitable for doing outdoor installations. The gel-filled cable can be laid directly in the ground, without any additional protection.
Inner conductor made of copper wire with a diameter of 1.63 mm and a double screening - Al/PET/Al foil glued to the dielectric + aluminum braid (86% coverage).
Key features:
- compliant with class A standard
- low attenuation
- excellent fit
- high screening efficiency
- PE sheath
- gel-filled cable
TRISET brand cables are compliant with the directive CPR and comply with the European standard EN 50575, which specifies the requirements for fire performance, test methods and evaluation of cables as construction materials.

The TRISET family of coaxial cables gained the Product of the Year award in "Accessories" category at SatKrak 2007 exhibition.
Declaration of RoHS compliance.
Screening efficiency above 100 dB allows parallel arrangement of many cables, which is indispensable in large multiswitch installations. The core of the TRISET-11 PE (diam. of 1.63 mm) is made of copper, guarantying low loss, durability (practically no corrosion), and satisfactory flexibility. The cable is suitable for building very extensive antenna and cable TV installations. Strict technological discipline ensures small variation of parameters.
Cable loss
Frequency [MHz] | Theoretical attenuation [dB/100m] | Measured attenuation [dB/100m] |
47 | 2.13 | 2.5 |
88 | 3.28 | 4.1 |
174 | 5.04 | 5.6 |
230 | 5.78 | 6.5 |
470 | 8.4 | 9.3 |
862 | 11.9 | 13.2 |
950 | 12.86 | 13.9 |
2150 | 20.28 | 21.0 |
2400 | 22.1 | 21.6 |
Return loss
Frequency | MHz | 5-470 | 470-862 | 862-2150 | 2150-2400 |
Theoretical | dB | >=23 | >=23 | >=20 | >=18 |
Measured | dB | 23 | 22 | 20 | 18 |
Shielding efficiency
Frequency | MHz | 30-2400 |
Screening factor | dB | >=100 |
According to EN50117 norm, coaxial cables are classified into C, B, A, A+, A++ groups.
Triset 11 cables feature the best screening efficiency among distribution cables available on the market (with parameters placing them between A+ and A++ class).
Classification of screening efficiency
Class | 30-1000 MHz | 2-3 GHz |
C | 75 | 55 |
B | 75 | 55 |
A | 85 | 65 |
A+ | 95 | 75 |
A++ | 105 | 85 |

Characteristics of the cable: BLUE - cable loss, RED - matching.
Price for 100 m
Specifications
Product type | Coaxial cable | ||
type | TRISET 11 | ||
Brand | TRISET | ||
Cable length | m | 100 | |
Applications | Outdoor | ||
Cable class | RG-11 | ||
CPR class | FCA | ||
Gel-filled cable | Yes | ||
Physical properties | |||
Impedance | Ohm | 75 | |
Screening efficiency class | A | ||
Transfer impedance TI | mΩ/m | <5 | |
Conductor | Material | Coper | |
Conductor | Diameter | mm | 1.63 |
Dielectric | foaming | Physical | |
Dielectric | Diameter | mm | 7.11 |
shield | |||
No. of plies | 2 | ||
First foil | bonded to dielectric | Yes | |
First foil | Material | Al/PET/Al | |
Dimensions | μm | 9/23/9 | |
total thickness | μm | 46 | |
Braid | Material | Aluminium | |
Braid | wire diameter | mm | 0.16 |
no. of wires | pcs. | 24 × 7 | |
winding angle | degree | 27 | |
braid coverage | % | 86 | |
sheath | Material | PE | |
sheath | thickness | mm | 1 |
Diameter | mm | 10.2 | |
Color | Black | ||
Electrical parameters | |||
Resistance at 20°C | Ω/km | 13.5 (shield) 8.3 (conductor) | |
capacity | pF/m | 52 | |
Wave reduction factor | % | 84 | |
Mechanical properties | |||
Operating temperature | °C | -30...+70 | |
Installation temperature | °C | -5...+40 | |
Minimum bending radius | mm | 50 (single) 100 (repeated) |