Coaxial Cable (75 ohm): Triset-11 PE 1.63/7.2/10.2, 100 dB (Fca, class A, gel-filled) [100m]

Code: E1025_100
€116.47
Price Disc. Quantity Validity
€116.47 0 % from 1 piece
Available
TRISET-11 PE (outdoor) double-shielded coaxial cable type RG11 with the internal conductor made of copper wire with a diameter 1.65 mm.
• Trunk cable,
• PE sheath - outdoor cable
• UV resistant
• Gel reducing the spread of moisture inside the cable
• Screening class: A
• 1.63 mm cooper core
• 86% aluminum braid coverage
• Double screening: foil/braid
• CPR class: Fca
• 100 m

Warranty

5-year warranty.

Support

Details

High-class coaxial cable from TRISET line. For use in community antenna installations and cable TV, especially for linking subnetworks. Due to PE sheath (polyethylene - UV resistant), it is suitable for doing outdoor installations. The gel-filled cable can be laid directly in the ground, without any additional protection.
Inner conductor made of copper wire with a diameter of 1.63 mm and a double screening - Al/PET/Al foil glued to the dielectric + aluminum braid (86% coverage).
Main features:
  • compliant with class A requirements,
  • LSZH sheath (LS0H),
  • low loss,
  • perfect matching,
  • high screening efficiency,
  • PE sheath,
  • gel-filled.
TRISET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
The cable is sold in the quantities:
100m E1025_100,
200m E1025_200.
The TRISET family of coaxial cables gained the Product of the Year award in "Accessories" category at SatKrak 2007 exhibition.
Declaration of RoHS compliance.
Screening efficiency above 100 dB allows parallel arrangement of many cables, which is indispensable in large multiswitch installations. The core of the TRISET-11 PE (diam. of 1.63 mm) is made of copper, guarantying low loss, durability (practically no corrosion), and satisfactory flexibility. The cable is suitable for building very extensive antenna and cable TV installations. Strict technological discipline ensures small variation of parameters.
Cable loss

Frequency [MHz]

Theoretical attenuation [dB/100m]

Measured attenuation [dB/100m]

47

2.13

2.5

88

3.28

4.1

174

5.04

5.6

230

5.78

6.5

470

8.4

9.3

862

11.9

13.2

950

12.86

13.9

2150

20.28

21.0

2400

22.1

21.6

Return loss

Frequency

MHz

5-470

470-862

862-2150

2150-2400

Theoretical

dB

>=23

>=23

>=20

>=18

Measured

dB

23
22
20
18
Shielding efficiency

Frequency

MHz

30-2400

Screening factor

dB

>=100

According to EN50117 norm, coaxial cables are classified into C, B, A, A+, A++ groups.
Triset 11 cables feature the best screening efficiency among distribution cables available on the market (with parameters placing them between A+ and A++ class).
Classification of screening efficiency

Class

30-1000 MHz
[dB]

2-3 GHz
[dB]

C

75

55

B

75

55

A

85

65

A+

95

75

A++

105

85

Characteristics of the cable: BLUE - cable loss, RED - matching.
Price for 100m

Specifications

Product type Coaxial cable
type TRISET 11
Brand TRISET
Cable length m 100
Applications Outdoor
Cable class RG-11
CPR class FCA
Gel-filled cable Yes
Physical properties
Impedance Ohm 75
Screening efficiency class A
Transfer impedance TI mΩ/m <5
Conductor Material Coper
Diameter mm 1,63
Dielectric foaming Physical
Diameter mm 7,11
shield
No. of plies 2
First foil bonded to dielectric Yes
Material Al/PET/Al
Dimensions μm 9/23/9
total thickness μm 46
Braid Material Aluminium
wire diameter mm 0,16
no. of wires pcs. 24 × 7
winding angle degree 27
braid coverage % 86
sheath Material PE
thickness mm 1
Diameter mm 10,2
Color Black
Electrical parameters
Resistance at 20°C Ω/km 13.5 (shield) 8.3 (conductor)
capacity pF/m 52
Wave reduction factor % 84
Mechanical properties
Operating temperature °C -30...+70
Installation temperature °C -5...+40
Minimum bending radius mm 50 (single) 100 (repeated)