Coaxial cable 75 Ohm TRISET 302 Dca class A+ 1.02/4.6/7.0 110 dB [500 m]

Code: E1006_500
€207.06
Price Disc. Quantity Validity
€207.06 0 % from 1 piece
Available
TRISET 302 Dca, Tri-shield type, made with LSZH jacket, intended for the construction of RTV/SAT installations. Reaction to fire class according to CPR - Dca-s2, d1, a1.
• Compliant with the class A+ standard
• Flammability class Dca-s2, d1, a1
• Compliant with the requirements of the MTBiGM regulation
• 1.02mm copper core
• Cable with tri-shield construction - triple screen
• Made in LSZH (LS0H) jacket - halogen-free insulation
• Low attenuation
• Excellent fit
• High shielding effectiveness - in the frequency band up to 2 GHz it meets the requirement of class A++
• Min. 77% braid coverage

Warranty

5-year warranty.

Support

Details

Coaxial cable 75 Ohm TRISET 302 Dca class A+ 1.02/4.6/7.0 110 dB [500 m]
Close-up of the Tri-Shield TRISET 302 Dca cable.
Coaxial cable 75 Ohm TRISET 302 Dca class A+ 1.02/4.6/7.0 110 dB [500 m]
Braid coverage 77% (aluminum)
High-quality Tri-Shield TRISET 302 Dca E1006 coaxial cable intended for both individual and collective installations. Cable with LSZH (LS0H) jacket - halogen-free insulation, used where greater safety in the event of fire is needed (tall and high-rise residential buildings, public utility buildings). It can be successfully used in installations of DVB-T2 digital terrestrial television, FM/DAB radio and multiswitch systems (DVB-T2 terrestrial television and DVB-S/S2 satellite).
Inner conductor made of copper wire with a diameter of 1.02 mm and a triple screen (first glued Al/PET/Al foil + 77% braiding + second Al/PET foil).
Key features:
  • compliant with the class A+ standard
  • flammability class Dca-s2, d1, a1
  • complies with the requirements of the MTBiGM regulation
  • 1.02 mm copper core
  • tri-shield cable - triple screen
  • made in LSZH (LS0H) jacket - halogen-free insulation
  • low attenuation
  • excellent fit
  • high shielding effectiveness - in the frequency band up to 2 GHz meets the requirement of class A++
  • min. 77% braid coverage
The high-quality, triple-shielded coaxial cable of RG6 category has the inner conductor made of copper wire with a diameter of 1.02 mm, which ensures low loss and durability. The copper wire core does not corrode and the cable is not stiff.
The TRISET 302 Dca E1006 coaxial cable has 77% braid coverage, guaranteeing a high level of shielding and protecting the useful signal against the influence of external interference.
In the case of parallel installation of many cables and long cable sections, it is recommended to use triple-screened cables. Effective screening over long distances eliminates the likelihood of so-called cable crosstalk. It consists of inducing unwanted signals in neighboring cables. This is visible on the screen by image interference - pixelation and freezing of scenes - as is the case with a weak signal or a low-quality signal.
The optimally selected flexibility of the jacket allows for easy installation of the cable both in cable ducts and in installation boxes or mounting boxes.
The cable is manufactured under strict quality standards, with tight tolerances.
In order to secure the minimum bend radius, flush mounted installations should be done with the use of protective conduits.
The Tri-Shield TRISET 302 Dca E1006 coaxial cable meets the EN50117 standard for shielding (class A+) in the frequency band 5 - 3000 MHz.
Construction Products Regulation (CPR) – coaxial and twisted-pair cables recommended for low-current systems in multi-family buildings.
TRISET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized standard that specifies reaction to fire performance requirements, test and assessment methods for cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
The 75 Ohm TRISET 302 Dca E1006 coaxial cable was tested by the notified body TÜV Rheinland with the number 1008 and obtained class Dca-s2, d1, a1 reaction to fire.
Characteristics of the TRISET 302 Dca cable coating
Name Parameter Requirements Requeirements Result TRISET 302 Dca
 Damage range  FS [m] flammability class Dca 1.8 Dca
 
 Heat release   rate  Peak HRR [kW] ≤ 400   40 
 Total heat release  THR1200 [MJ]  ≤ 70  12 
 Fire growth rate  FIGRA [W/s] ≤ 1300 155
 Vertical flame spread  H [mm] ≤ 425 65
 Total smoke production  TSP [mm2] in time 1200 sec smoke production for subclass s1a   ≤ 50 26 s1a
 
 Smoke production rate  Peak SPR   [m2/sek]  ≤ 0.25 0.08
 Transmittance  T [%]   ≥ 80 89 
 Flaming droplets  Drops [sec] burning drops for subclass d1 no drops brak d1
 Acidity  pH acidity for subclass a1 4.3 ≥ 5.3 a1
 Conductivity  Conductivity   [μS/mm] ≤ 2.5 0.3

 

For more on cable fire resistance classes, read The CPR Directive - the new cable order
According to the EN50117 standard, coaxial cables are divided into classes: C, B, A, A+, A++, depending on the screening effectiveness.
Classes of screening efficiency
Class 5-30 MHz [mΩ/m] 30-1000 MHz [dB] 1-2 GHz [dB] 2-3 GHz [dB]
C 50 75 65 55
B 15 75  65 55
A 5 85  75 65
A+ 2,5 95  85 75
A++ 0,9 105  95 85
Measurement results of the most important technical parameters.
Coupling impedance in the frequency range 5-30 MHz
and shielding of the TRISET 302 Dca cable in the frequency range 30-3000 MHz
In the frequency band up to 2 GHz, meets the requirement of class A++
Insertion loss in the 5-3000 MHz range
Cable reflection loss in the frequency range 5-3000 MHz.
Smith chart showing the wave impedance of the cable.
Measurements taken at both ends of a 100 m section of cable. Deviations from the nominal value of 75Ω
not exceeding 1% guarantee perfect impedance matching in the entire transmission path.
The speed of signal propagation in a cable in the frequency range 5-1000 MHz.

Specifications

Product type Coaxial cable
type
Brand TRISET
Cable length m 500
Applications Indoor
Cable class RG-6
Compliance with relevant national legislation Yes
CPR class Dca
Physical properties
Impedance Ohm 75
Screening efficiency class A+
Transfer impedance TI mΩ/m < 2,5
Conductor Material Coper
Diameter mm 1,02
Dielectric foaming Physical
Diameter mm 4,6
shield
No. of plies 3
First foil bonded to dielectric Yes
Material Al/PET/Al
Braid Material Aluminium
wire diameter mm 0,12
no. of wires pcs. 16 × 8
winding angle degree 26,69
braid coverage % 77
Second foil Material Al/PET
sheath Material LSZH
Diameter mm 7,0
Color White
Electrical parameters
Resistance at 20°C Ω/km 32.12 (shield) 21.91 (conductor)
capacity pF/m 52,5
Mechanical properties
Operating temperature °C -30...+70
Installation temperature °C -10...+40
Packaging
Spool Diameter mm 370
Width mm 300
Cable length m 500

Videos

Installation of MASTER F-type and BNC connectors

A short presentation how to compress F connector on TRISET-113 cable and BNC connector on RG-59 cable.

Terminating lines in telecommunication junction box

Practical implementation of a home junction box.