| Replacements | |
| E80362 | F-connector F MASTER 11 (compressed on Triset-11) |
- wide operating band - up to 2.4 GHz,
- waterproof termination of the cable,
- resistance to corrosion - made of non-ferrous metals and highest-quality dielectric,
- very low loss in the whole operating band,
- perfect matching to the transmission line within the whole operating band,
- simple and quick assembly: longitudinal compression,
- properly compressed connection is highly resistant to break, due to dual compression rings,
- full integration with the cable,
- perfect contact of the core pin and socket opening,
- matched to the TRISET-11 cables,
- the cable to be stripped with E80074 tool (1/4" x 1/4")
- to be compressed with PCT-AIO-CT E80075 compressing tool,
- the connector can be screw down with 7/16" wrench,
- many patented technologies,
- quick and easy assembly, as well as stability of operation of the equipment are really worth the price.
Name | Compression F Connector: PCT DRS-11QP (for TRISET-11) |
Code | E80360 |
Material | |
Body material | C 360 brass |
Body finish | Nickel tin |
O-ring material | Ethylene-propylene rubber |
Physical dimensions | |
Body outer diameter | 12.7mm |
Body inner diameter | 10.6mm |
Electrical properties | |
Return loss | -28dB -28dB to 1GHz |
Insertion loss | -0.2dB to 1GHz |
RFI shielding | -80dB |
Parameter | Specification | Requirement |
Cable retention | SCTE IPS-TP-401 | pull force > 178 N |
Chemical resistance | BLCR GR-1503-CORE 4.7 | no cracking or swelling |
Corrosion resistance | BLCR GR-1503-CORE 3.2.1 | 1000 hours in salt spray |
Dielectric strength | BLCR GR-1503-CORE 3.5.2 | 1 kV AC for 1 minute |
Equipment interface | BLCR GR-1503-CORE 3.2.4 | 10 matings with torque 4.47 Nm without damage |
Insertion loss | BLCR GR-1503-CORE 3.5.3 | < 0.05 dB to 350 MHz, |
Installation force | SCTE IPS-TP-004 | < 89 N |
Loosening torque | BLCR GR-1503-CORE 4.2 | ≥ 3.35 Nm |
Moisture migration | SCTE IPS-TP-013 | no dye penetration after 5 days of temperature cycling |
Ozone degradation | BLCR GR-1503-CORE 4.1 | 70 hours exposure |
Return loss | SCTE IPS-TP-110 | > 30 dB to 1 GHz |
Salt fog | BLCR - ASTM B 117 | return loss > 30 dB to 1 GHz |
Shielding effectiveness | SCTE IPS-TP-403 | > 100 dB to 300 MHz, |
Temperature cycling with humidity | BLCR GR-1503 4.1 | pull force > 178 N |
UV degradation | BLCR GR-1503-CORE 4.8 | no change after 7 days |
Vibration | BLCR GR-1503-CORE 4.6 | loosening torque after vibration > 3.57 Nm |
| Replacements | |
| E80362 | F-connector F MASTER 11 (compressed on Triset-11) |