The GPJ09-9401 round joint box can handle 12, 24 or 36 optical splices. It is suitable for various installation scenarios.
• IP 68
• Can be used in overhead systems, with telecommunication conduits etc.
• Compact size
• Space for 36 fiber optic splices
• 3 splice cassettes
• 2 input and 2 output ports
• Sealing material: self-vulcanizing rubber
• Can be used in overhead systems, with telecommunication conduits etc.
• Compact size
• Space for 36 fiber optic splices
• 3 splice cassettes
• 2 input and 2 output ports
• Sealing material: self-vulcanizing rubber
The GFP-12F-T-2 fiber optic coupler allows you to make a fiber optic connection including up to 12 splices. Flat design allows it to be used in locations with limited space.
• IP68 protection class
• Suitable for telecom ducting, underground systems
• Compact size
• Space for 12 fiber optic splices
• Suitable for telecom ducting, underground systems
• Compact size
• Space for 12 fiber optic splices
Horizontal straight-through joint repair joint. It is designed for 2 cables with an outer diameter not exceeding 6.5 mm.
• Material: PC+ABS
• UV-resistant housing
• Protection rating: IP65
• Can protect up to 4 splices
• UV-resistant housing
• Protection rating: IP65
• Can protect up to 4 splices
GFP-6P fiber optic coupler can be used in ground systems as a repair element or coupler for DAC cables with a maximum of 12 fibers.
• Material: PC+ABS
• UV-resistant housing
• Protection rating: IP65
• Can protect up to 6/ 12 splices
• UV-resistant housing
• Protection rating: IP65
• Can protect up to 6/ 12 splices
The GFP-8E pole-mounted coupler has two main cable ports and 8 (+1) subscriber DROP cable ports.
• BOX type housing
• 3 ports for trunk cables
• 8 (+1) ports for subscriber cables
• Cassette for 12 splices
• Space for mounting 4 SC simplex/LC duplex adapters.
• 3 ports for trunk cables
• 8 (+1) ports for subscriber cables
• Cassette for 12 splices
• Space for mounting 4 SC simplex/LC duplex adapters.
The GFP-8B wall-mounted distribution frame has 2 inputs for the trunk cable and 12 outputs for subscriber cables. It is designed for wall mounting. The design allows for 12 SC simplex/LC duplex and fiber splices (12/24).
• The distribution frame is designed for wall and pole mounting
• Space for 12 SC simplex / LC duplex adapters
• Space for 12/24 splices
• Convenient spare fiber management
• 2 input ports
• 12 output ports
• Space for 12 SC simplex / LC duplex adapters
• Space for 12/24 splices
• Convenient spare fiber management
• 2 input ports
• 12 output ports
The MDU B16 pole-mounted joint box has two main cable ports and 16 DROP subscriber cable ports.
• BOX type housing
• 2 trunk cable ports (uncut port)
• 16 subscriber cable ports
• Cassette for 24 splices
• Room for mounting 16 SC simplex adapters
• Can be mounted on a pole
• 2 trunk cable ports (uncut port)
• 16 subscriber cable ports
• Cassette for 24 splices
• Room for mounting 16 SC simplex adapters
• Can be mounted on a pole
The GFP-16D hanged distribution frame has two inputs for trunk cables and 16 outputs for subscriber cables. It is designed for wall or pole mounting.
• The distribution frame is designed for wall and pole mounting
• Space for 16 SC simplex/LC duplex adapters
• Space for 116 splices
• Convenient spare fiber management
• 2 input uncut ports
• 16 subscriber outputs
• Space for 16 SC simplex/LC duplex adapters
• Space for 116 splices
• Convenient spare fiber management
• 2 input uncut ports
• 16 subscriber outputs
The GFP-16G hanged distribution frame has two inputs for trunk cables and 16 outputs for subscriber cables. It is designed for wall or pole mounting.
• The distribution frame is designed for wall and pole mounting
• Space for 16 SC simplex/LC duplex adapters
• Space for 116 splices
• Convenient spare fiber management
• 2 input uncut ports
• 16 subscriber outputs
• Space for 16 SC simplex/LC duplex adapters
• Space for 116 splices
• Convenient spare fiber management
• 2 input uncut ports
• 16 subscriber outputs