Fiber-optic Cable: Fibertechnic DAC Z-XOTKtcdD 24J (24x9/125 ITU-T G.652D)

Support

Details

Fiber-optic Cable: Fibertechnic DAC Z-XOTKtcdD 24J (24x9/125 ITU-T G.652D)
Visualization of the cable
The Fibertechnic DAC 24J Z-XOTKtcdD cable with Corning SMF-28 Ultra fibers (L79224) is designed for installataion directly in the ground. It has a HDPE sheath with high crush resistance (4000 N), which also makes it resistant to low temperatures. It can be employed on the last mile of a FTTH system, as well as in any installation that requires terrestrial cables, where casing pipes cannot be used for additional protection.
The cable can also be installed in existing telecommunication ducts: the maximum pulling force during installation equals 1200 N.
The central tube contains 24 single-mode G.652D fibers.
The central tube is filled with gel to protect fibers against humidity and vibrationa, while the cable as such has a waterblock design. It is additionally reinforced with 2 FRP rods with a diameter of 0.9 mm.
Despite its high mechanical resistance, the cable is very easy to process. No dedicated tools are required to remove the outer sheath: a simple cleaver (to perform a cut of several centimeters along the central tube) and a pair of pliers (to tear up the outer sheath with FRP rods) are all you need. To cut the tube, use the Ideal L5922 stripper.
Key features
  • HDPE sheath and structure allowing to deploy the cable directly in the ground
  • Crush resistance: 4000 N
  • Max. pulling force: 1200 N
  • 2 x FRP rods (0.9 mm)
  • Central tube filled with hydrophobic gel
Specifications
Name Fibertechnic DAC Z-XOTKtcdD
Code L79224
Number of fibers
24
Fiber type
G.652D Corning
Number of tubes
1
Tube diameter 2 mm
Cable diameter
6 mm
Sheath (jacket) HDPE
Reinforcement 2x FRP rods (0.9 mm)
Max. pulling force (during installation) 1200 N
Max. pulling force (during operation) 800 N
Crush resistance
4000 N
Operating temperature
-20...+70°C
Min. bending radius
120 mm
Weight
48 kg/km

Specifications

Product type Fiber optic cable
Brand FIBERTECHNIC
Name Z-XOTKTCDD
Cable type Earth Dose
Number of fibers 24
Fibers type Single-mode, 9/125
Fibers standard G.652D
buffer 250 μm
CPR class FCA
Outer sheath material HDPE
Hydrophobic gel No
Gain FRP rods
Central tube Yes
Outer diameter mm 6
Central tube diameter mm 2
Crush strength N 4000
Maximum pulling force dynamic N 1200
Maximum pulling force static N 800
Min. bending radius static mm no data
Min. bending radius installation mm 120
Temperature range operation °C -20...70
Temperature range installation °C no data
storage °C no data
Weight kg/km 48
Cable length m Sold per meter