Support
Details
The ISC-BPR2-W12 motion detector is dedicated for use in intrusion alarm systems. The Blue Line Gen2 PIR Motion Detectors (ISC-BPR2) use two Fresnel lenses designed to produce sharply-focused images throughout the field of view, providing superior response to intruders. First Step Processing (FSP) almost instantly responds to human targets without producing false alarms from other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing. This eliminates the need for the installer to select the sensitivity level, thus improving ease of installation and reliability. The small unobtrusive detector is simple to install and does not need field adjustment. The sliding self‑locking enclosure has an integrated bubble level and custom gap‑free, lift‑gate style terminal block to make the installation easier.
Key features:
- passive infrared detector (PIR),
- First Step Processing (FSP) with quick respond
- wide detection area of 12x12 m
- dynamic temperature compensation
- blue LED indicator of motion detection / alarm
- LED switching-off option
- anti-tamper protection against opening the enclosure
- two Fresnel lenses
- ability to exchange the lenses
Specifications
Model | ISC-BPR2-W12 | ||
Product type | Alarm detector | ||
Brand | Bosch | ||
type | Przewodowa | ||
Color | White | ||
Housing material | Plastic | ||
Compatibility | Wired systems | ||
Parameters | |||
Detection paths | PIR | ||
Installation | Indoor | ||
Recommended mounting height | m | 2.2 – 2.75 | |
Max. detection range | Length | m | 12 |
Max. detection range | Width | m | 12 |
Detection angle | ° | 85 | |
LED indicator for signaling | Yes | ||
Number of LED indicator colors | 1 | ||
Digital temperature compensation | Yes | ||
Built-in spirit level | Yes | ||
Replaceable lens | Yes | ||
Anti-tamper protection | Yes | ||
Others | |||
Supply voltage | DC | V | 12 +/-15% |
Standby current drawn | mA | 10 | |
Maximum current consumption | mA | 10 | |
Environmental class | II | ||
Compliance with standards | EN50102, EN50130-5, EN50131-2-2, EN60529 | ||
Operating temperature | °C | -30...+55 | |
Max. humidity | % | 95 | |
Dimensions | mm | 105 × 61 × 44 | |
Weight | kg | 0.1 |