A short instructional video on crimping RJ-45 connector on a category 6 UTP cable, according to the EIA/EIA 568B standard. The items used: NETSET U/UTP cat. 6 cable, 8-pin RJ-45 modular plug, modular plug boot, HT-210N crimping tool, cable tester NS-468AT.
Price | Disc. | Quantity | Validity |
---|---|---|---|
€165.65 | 0 % | from 1 piece |
• Category 5e
• Flammability class: B2ca
• Application: indoor
• PVC coating
• Wire diameter 0.49 mm (24 AWG)
• Carton 305 m
Details
Specifications
Name | NETSET U/UTP cat. 5e | ||
Product type | twisted-pair cable | ||
Manufacturer | Dipol | ||
Brand | NETSET | ||
Cable type | U/UTP | ||
Applications | Indoor | ||
Category | 5e | ||
Cable length | m | 305 | |
CPR class | B2ca-s1a,d0,a1 | ||
Physical properties | |||
Conductor | Material | Cooper | |
Diameter | mm | 0,49 | |
Conductor insulation | Material | HDPE (polyethylene) | |
Diameter | mm | 0,88 | |
Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
sheath | Material | FR-LSZH | |
Diameter | mm | 5,4 | |
thickness | mm | 0,7 | |
Color | RAL7032 (gray) | ||
Gel filled | No | ||
Carrier cable | No | ||
Rip-cord | Yes | ||
Spline | No | ||
Length marker print error | % | <0.5 | |
Electrical parameters | |||
Impedance | Ohm | 100 | |
Nominal Velocity of Propagation NVP | % | 68 | |
Delay skew | ns/100 m | <45 | |
DC resistance | Ohm/100 m | 9,5 | |
Resistance asymmetry | % | <5 | |
Return Loss | 1 MHz | ≥dB | 20 |
4 MHz | ≥dB | 23 | |
8 MHz | ≥dB | 24,5 | |
10 MHz | ≥dB | 25 | |
16 MHz | ≥dB | 25 | |
20 MHz | ≥dB | 25 | |
25 MHz | ≥dB | 24,3 | |
31.25 MHz | ≥dB | 23,6 | |
62.5 MHz | ≥dB | 21,5 | |
100 MHz | ≥dB | 20,1 | |
Loss | 1 MHz | ≤dB | 2 |
4 MHz | ≤dB | 4,1 | |
8 MHz | ≤dB | 5,8 | |
10 MHz | ≤dB | 6,5 | |
16 MHz | ≤dB | 8,2 | |
20 MHz | ≤dB | 9,3 | |
25 MHz | ≤dB | 10,4 | |
31.25 MHz | ≤dB | 11,7 | |
62.5 MHz | ≤dB | 17 | |
100 MHz | ≤dB | 22 | |
NEXT (near-end crosstalk) | 1 MHz | ≤dB | 65,3 |
4 MHz | ≤dB | 56,3 | |
8 MHz | ≤dB | 51,8 | |
10 MHz | ≤dB | 50,3 | |
16 MHz | ≤dB | 47,2 | |
20 MHz | ≤dB | 45,8 | |
25 MHz | ≤dB | 44,3 | |
31.25 MHz | ≤dB | 42,9 | |
62.5 MHz | ≤dB | 38,4 | |
100 MHz | ≤dB | 35,3 | |
PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 62,3 |
4 MHz | ≥dB | 53,3 | |
8 MHz | ≥dB | 48,8 | |
10 MHz | ≥dB | 47,3 | |
16 MHz | ≥dB | 44,4 | |
20 MHz | ≥dB | 42,8 | |
25 MHz | ≥dB | 41,3 | |
31.25 MHz | ≥dB | 39,9 | |
62.5 MHz | ≥dB | 35,4 | |
100 MHz | ≥dB | 32,3 | |
ELFEXT | 1 MHz | ≥dB | 63,8 |
4 MHz | ≥dB | 51,8 | |
8 MHz | ≥dB | 45,7 | |
10 MHz | ≥dB | 43,8 | |
16 MHz | ≥dB | 39,7 | |
20 MHz | ≥dB | 37,8 | |
25 MHz | ≥dB | 35,8 | |
31.25 MHz | ≥dB | 33,9 | |
62.5 MHz | ≥dB | 27,9 | |
100 MHz | ≥dB | 23,8 | |
PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 60,8 |
4 MHz | ≥dB | 48,8 | |
8 MHz | ≥dB | 42,7 | |
10 MHz | ≥dB | 40,8 | |
16 MHz | ≥dB | 36,7 | |
20 MHz | ≥dB | 34,8 | |
25 MHz | ≥dB | 32,8 | |
31.25 MHz | ≥dB | 30,9 | |
62.5 MHz | ≥dB | 24,9 | |
100 MHz | ≥dB | 20,8 | |
Mechanical properties | |||
Operating temperature | °C | -20...+70 | |
Installation temperature | °C | 0...+50 | |
Minimum bending radius for indoor installation | Diameter | >8 |
Videos
How to attach RJ-45 connector to cat 5 UTP cable? Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.