€0.62
| Price | Disc. | Quantity | Validity |
|---|---|---|---|
| €0.62 | 0 % | from 1 piece |
Available
The NETSET F/UTP CAT 5e is the finest-quality twisted pair cable designed for professional data transmission systems inside buildings.
• Cable type: F/UTP
• Category 5e
• Applications: indoor
• PVC sheath
• Core diameter 0.5 mm (24 AWG)
• Sold by the meter
• Category 5e
• Applications: indoor
• PVC sheath
• Core diameter 0.5 mm (24 AWG)
• Sold by the meter
Details
Note: The maximum length of the ordered section is 300 m.
NETSET cables are compliant with Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
NETSET BOX F/UTP 5e E1515 cable has been examined by DELTA DANSK ELEKTRONIK LYS OG AKUSTIK notified body (NB 0199) and got Eca reaction to fire classification.
NETSET FTP 5e E1515 is a top quality indoor FTP cable (twisted-pair cable) designed for use in professional computer networks inside buildings. Shielding layer made of aluminum foil allows to minimize crosstalk and interference with the external environment.
Distinguishing features of NETSET FTP CAT 5e:
- highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee
- preliminary quality control of materials and thorough tests of the final product
- meter marker
- solid wires of 0.5 mm diameter (24 AWG)
- wire insulation made of homogeneous, colored PE; outer diameter: 1.0 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue
- protected with polyester foil
- shielding layer made of aluminum foil
- sheath made of gray PVC (RAL 7032), of 6.2 mm diameter
- length error less than 0.5%
NETSET FTP CAT 5e E1515_1 Ethernet cable is manufactured in compliance with EN 50173, ISO/IEC 61156-5 edition:2002, ISO/IEC 11801 standards.
NETSET cables come with a 15-year warranty
The manufacturer guarantees the stability of the parameters for a period of 15 years. The condition for maintenance of the guarantee is observance of the principles of packaging, storage and transport described in the PN-70 E-79100 standard and the principles of operation described in the PN-EN 50174-1 standard.
The NETSET FTP CAT 5e E1515_1 cable can be used in a wide temperature range: -20oC...+50oC, and installed between 0oC and +50 oC.
NETSET brand cables are compliant with the directive CPR and comply with the European standard EN 50575, which specifies fire performance requirements, test methods and evaluation of cables as building materials.
NETSET FTP CAT 5e cable has been tested by
Central Testing Laboratory
of the
National Institute of Telecommunications in Warsaw, Poland
and got
CERTIFICATE OF THE INSTITUTE
- Path (pair) resistance testing.
| Pair | Wire | Wire resistance [Ω/km] | Resistance asymmetry [%] | |
| FTP Cat. 5e | 1 | a | 82.181 | 0.28 |
| b | 82.407 | |||
| 2 | a | 84,457 | 1.33 | |
| b | 85.583 | |||
| 3 | a | 82.933 | 0.83 | |
| b | 83.620 | |||
| 4 | a | 81.619 | 0.07 | |
| b | 81.566 | |||
| Required | - | - | ≤150 | ≤3.0 |
- +++ Checking effective capacitance and capacitance asymmetry.
| Pair | Effective capacitance [nF/km] | Capacitance asymmetry [pF/km] | |
| FTP Cat. 5e | 1 | 48.08 | 403 |
| 2 | 50.69 | 2 | |
| 3 | 48.76 | 382 | |
| 4 | 47.63 | 79 | |
| Required | - | ≤55 | ≤1600 |
- Insulation testing.
| Pair | Wire | Insulation resistance [MΩ/km] | |
| FTP Cat. 5e | 1 | a | 3.5 · 105 |
| b | 3.8 · 105 | ||
| 2 | a | 4.5 · 105 | |
| b | 4.8 · 105 | ||
| 3 | a | 3.9 · 105 | |
| b | 4,6 · 105 | ||
| 4 | a | 3.8 · 105 | |
| b | 7.0 · 104 | ||
| Required | - | - | ≥150 |
- Tests of electric strength of insulation.
| Test method | Test voltage [VAC] | |
| Applied | Required | |
| Voltage applied between connected in parallel all a wires and all b wires | 1000 | 1000 |
- End-to-end attenuation testing.
| Pair | Effective attenuation [dB] | |
| FTP Cat. 5e | 1 | 21.1 |
| 2 | 22.3 | |
| 3 | 21.8 | |
| 4 | 22.6 | |
| Required | - | ≤24.9 |
- Near End Cross Talk (NEXT) testing.
| Pair to pair | NEXT [dB] | |
| FTP Cat. 5e | 1-2 | 69.5 |
| 1-3 | 65.2 | |
| 1-4 | 64.8 | |
| 2-3 | 66.1 | |
| 2-4 | 68.5 | |
| 3-4 | 69.0 | |
| Required | - | ≥34.0 |
- Return loss testing.
| Pair | Return loss [dB] | |
FTP Cat. 5e | 1 | 20.7 |
| 2 | 22.9 | |
| 3 | 26.2 | |
| 4 | 24.1 | |
| Required | - | ≥19.4 |
- Total Near End Cross Talk (PS-NEXT) testing.
| Pair | PS-NEXT [dB] | |
| FTP Cat. 5e | 1 | 61.25 |
| 2 | 62.92 | |
| 3 | 61.67 | |
| 4 | 62.22 | |
| Required | - | ≥31.0 |
NETSET FTP 5e fulfills all requirements for Category 5e cables, with a large safety margin.
Price for 1 m.
Specifications
| Name | NETSET F/UTP cat 5e | ||
| Product type | twisted-pair cable | ||
| Manufacturer | DIPOL | ||
| Brand | NETSET | ||
| Cable type | F/UTP | ||
| Applications | Indoor | ||
| Category | 5e | ||
| Cable length | m | Sold per meter | |
| CPR class | Eca | ||
| Physical properties | |||
| Conductor | Material | Cooper | |
| Conductor | Diameter | mm | 0.5 |
| Conductor insulation | Material | HDPE (polyethylene) | |
| Conductor insulation | Diameter | mm | 1 |
| Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
| Conductor shield | Material | Al/Mylar | |
| sheath | Material | PVC | |
| sheath | Diameter | mm | 6.2 |
| thickness | mm | 0.55 | |
| Color | RAL7032 (gray) | ||
| Gel filled | No | ||
| Carrier cable | No | ||
| Rip-cord | Yes | ||
| Spline | No | ||
| Length marker print error | % | <0.5 | |
| Electrical parameters | |||
| Impedance | Ohm | 100 | |
| Nominal Velocity of Propagation NVP | % | 67 | |
| Delay skew | ns/100 m | <45 | |
| DC resistance | Ohm/100 m | 9.5 | |
| Resistance asymmetry | % | <5 | |
| Return Loss | 1 MHz | ≥dB | 20 |
| Return Loss | 4 MHz | ≥dB | 23 |
| 8 MHz | ≥dB | 24.5 | |
| 10 MHz | ≥dB | 25 | |
| 16 MHz | ≥dB | 19 | |
| 20 MHz | ≥dB | 25 | |
| 25 MHz | ≥dB | 24.3 | |
| 31.25 MHz | ≥dB | 23,6 | |
| 62.5 MHz | ≥dB | 21.5 | |
| 100 MHz | ≥dB | 20.1 | |
| Loss | 4 MHz | ≤dB | 4,1 |
| 8 MHz | ≤dB | 5,8 | |
| 10 MHz | ≤dB | 6.5 | |
| 16 MHz | ≤dB | 8.2 | |
| 20 MHz | ≤dB | 9.3 | |
| 25 MHz | ≤dB | 10.4 | |
| 31.25 MHz | ≤dB | 11.7 | |
| 62.5 MHz | ≤dB | 17 | |
| 100 MHz | ≤dB | 22 | |
| NEXT (near-end crosstalk) | 1 MHz | ≤dB | 65.3 |
| NEXT (near-end crosstalk) | 4 MHz | ≤dB | 56.3 |
| 8 MHz | ≤dB | 51.8 | |
| 10 MHz | ≤dB | 50.3 | |
| 16 MHz | ≤dB | 47.2 | |
| 20 MHz | ≤dB | 45.8 | |
| 25 MHz | ≤dB | 44.3 | |
| 31.25 MHz | ≤dB | 42.9 | |
| 62.5 MHz | ≤dB | 38.4 | |
| 100 MHz | ≤dB | 35.3 | |
| PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | 62.3 |
| PSNEXT (power sum near-end crosstalk) | 4 MHz | ≥dB | 53.3 |
| 8 MHz | ≥dB | 48.8 | |
| 10 MHz | ≥dB | 47.3 | |
| 16 MHz | ≥dB | 44.4 | |
| 20 MHz | ≥dB | 42.8 | |
| 25 MHz | ≥dB | 41.3 | |
| 31.25 MHz | ≥dB | 39.9 | |
| 62.5 MHz | ≥dB | 35.4 | |
| 100 MHz | ≥dB | 32.3 | |
| ELFEXT | 1 MHz | ≥dB | 63.8 |
| ELFEXT | 4 MHz | ≥dB | 51.8 |
| 8 MHz | ≥dB | 45.7 | |
| 10 MHz | ≥dB | 43.8 | |
| 16 MHz | ≥dB | 39.7 | |
| 20 MHz | ≥dB | 37.8 | |
| 25 MHz | ≥dB | 35.8 | |
| 31.25 MHz | ≥dB | 33.9 | |
| 62.5 MHz | ≥dB | 27.9 | |
| 100 MHz | ≥dB | 23.8 | |
| PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | 60.8 |
| PSELFEXT (power sum far-end crosstalk) | 4 MHz | ≥dB | 48.8 |
| 8 MHz | ≥dB | 42.7 | |
| 10 MHz | ≥dB | 40.8 | |
| 16 MHz | ≥dB | 36.7 | |
| 20 MHz | ≥dB | 34.8 | |
| 25 MHz | ≥dB | 32.8 | |
| 31.25 MHz | ≥dB | 30.9 | |
| 62.5 MHz | ≥dB | 24.9 | |
| 100 MHz | ≥dB | 20.8 | |
| Mechanical properties | |||
| Operating temperature | °C | -20...+70 | |
| Installation temperature | °C | 0...+50 | |
| Minimum bending radius for indoor installation | Diameter | >8 | |

![NETSET U/FTP 5e shielded twisted-pair cable, indoor use [1 m]](https://static.dipol.com.pl/images/images/E1515_CPR_.jpg)