Support
Details

The rH-R1S1 module is a combined single relay with transmitter and contact input. The module sends information about the opening and closing of the contact to the system and controls the relay, which can switch on any electrical circuit. Communication with the server takes place by means of radio. The module has a physical input for the connection of one monostable potential free contact as well as one relay switch. The load can be resistive, inductive or capacitive, in both AC and DC circuits. The rH-R1S1 is particularly suitable for controlling a ventilation fan, lighting and the activation of wall outlets.
Symbol in design and configuration software:

The symbol of rH-R1S1
The rH-R1S1 module is represented by object that consists of one binary (two-state) input and relay output. The input controls the relay, and the output provides information about the state of the relay. Additionally, the object has one digital input and output. Shorting or opening of the contact changes the logic state of the output.
Installation:

- Switch off the AC line and make sure that there is no voltage.
- Connect the wires according to the diagram above.
- Mount the module in a suitable installation box.
- Adjust the antenna wire parallel to one of the server antennas, as far as possible from the other wires.
- Switch on the AC line.
- Register the device in the system.
- Close the installation box.

In the diagram above the rH-R1S1 module is connected with a monostable switch and a lamp.
Example applications:


In the diagram above, in the case of motion detection the F1802 motion and temperature sensor provides logic state "1" and the relay of the F1211 module switches on the lamp. Additionally, the tº output can be used to control a heater, air conditioning system etc. The second channel of the F1211 module can be used e.g. for switching light in another room.
About the system:
Specifications
Name | F&Home Radio rH-R1S1 |
Code | F1211 |
Power | 230 VAC / 50 Hz |
RF communication band [MHz] | 868 |
Communication mode | two-way |
Data encryption | YES |
Open space range | 100 m |
Load | 1x 4A / 250 VAC |
Relay input (triggered by L or N level) | 1x (contact) |
Operating temperature range | -20ºC ... +50ºC |
Operating humidity / environment | <= 85% (no condensation of water vapor) / no aggressive gasses |
Protection | against overheating |
Dimensions [mm] | 48x48x22 |
Ingress protection rating | IP 20 |

Specifications
Nazwa | Moduł rH-R1S1 |
Kod | F1211 |
Zasilanie | AC 230 V 50 Hz |
Łącze radiowe [MHz] | 868 |
Rodzaj transmisji | dwukierunkowa |
Kodowanie | TAK |
Zasięg w otwartej przestrzeni | 100 m |
Odbiorniki | 1 x 4A / AC 250V |
Wejście wyzwalane poziomem L lub N | 1x stykowe |
Temperatura pracy | -20...50 ºC |
Wilogotność | <= 85% (bez kondensacji pary i gazów agresywnych) |
Zabezpieczenia | przed przegrzaniem |
Wymiary [mm] | 48x48x22 |