€143.54
Price | Disc. | Quantity | Validity |
---|---|---|---|
€143.54 | 0 % | from 1 piece |
Available
Replacements
ZPZ-12 Signal has been designed to provide comprehensive protection of SMATV systems, in particular multiswitch installations.
• Interior/exterior box made of PA 11 aluminium alloy, powder-coated in RAL 7035
• The cable holes are placed through the box
• Number of interconnectors 12
• Operating bandwidth 5-2400 MHz
• Maximum current at 8/20µs 8 kA
• Breakdown voltage at 100 V/s DC 230+/-42 V
• Protection level at 1 kV/µs ≤ 800 V
• The cable holes are placed through the box
• Number of interconnectors 12
• Operating bandwidth 5-2400 MHz
• Maximum current at 8/20µs 8 kA
• Breakdown voltage at 100 V/s DC 230+/-42 V
• Protection level at 1 kV/µs ≤ 800 V
Details
ZPZ-12 Signal R48612 transitional set of 12 surge protections has been designed for comprehensive protection of SMATV systems, especially multiswitch installations. It allows to protect terrestrial and satellite TV reception system against overvoltages and voltages induced in the cables by lightning discharges.
The box has been equipped with 12 Signal TV-Sat surge protectors R48602 that can protect:
- 2 satellite multiswitch paths (8 cables in total - 4 polarisation-band pairs for each satellite)
- 2 radio channels (FM, DAB)
- 2 DVB-T terrestrial TV paths (UHF1, UHF2)
Key features:
- 12 protectors allowing protection of 12 signal paths
- inner/outer box made of PA 11 aluminium alloy, powder-coated in RAL 7035
- sealed door, grounded, mounted on two hinges, lockable with cylinder lock
- wall assembly
- holes with cable glands for easy insertion and removal of cables
- grounding clamp fi 6 with cable grommet
- carton packaging
The cables coming out of the box should be connected to the first active elements in the installation (multiswitch bus amplifiers, terrestrial TV amplifiers etc.). +++The box has to be earthed according to current regulations.
The construction of the box allows for the use of different types of F connectors and easy organization of coaxial cables. The recommended cable for connecting the protectors with antenna equipment is Triset-113 PE E1017, the best F-connectors are MASTER F 113 E80342. The output cables can also be Triset-113 PE E1017, or - in the case of long distances - Triset-11 PE E1025 (terminated with MASTER 11 E80362 F connectors).
Specifications
Product type | Surge protection | ||
Applications | SMATV | ||
Brand | SIGNAL | ||
Name | ZPZ-12 | ||
Number of protectors | 12 | ||
Installation | On the wall, 4 holes ø 5.6 mm 234/180 | ||
Cable routing | pass-through | ||
Outdoor/indoor mounting | Yes/Yes | ||
Number of input holes | 12 | ||
Number of output holes | 12 | ||
Diameter of input/output holes. | mm | 16.5 | |
Cable glands | number | pcs. | 24 |
Cable glands | Material | TPE thermoplastic elastomer | |
Wire diameter | mm | 5 – 11 | |
Box material | Aluminum alloy PA 11 | ||
Type of finishing | RAL 7035 paint | ||
Door | Grounded, rubber seal in body, two hinges, cylinder lock with key | ||
Grounding terminal of the box | Yes, ø 6 mm, cable eyelet | ||
Dimensions of the box | mm | 305 × 250x110 | |
Weight | kg | 2 | |
Protector information | |||
Operating band | MHz | 5 – 2400 | |
Input | F-socket | ||
Output | F-socket | ||
Insertion loss | dB | Typical 0.8 for 1 GHz, Typical 1.2 for 2 GHz | |
Matching | dB | Typical 12 | |
maximum current | kA | 8 for 8/20 µs | |
Impedance | Ohm | 75 | |
DC-current transition | Yes | ||
DC breakdown voltage at 100 V/s | V | 230+/-42 | |
Shielding factor | dB | > 90 (EN 50083-2/A1, klasa A) | |
Protection level at 1 kV/µs | V | ≤ 800 |