Universal optical cable ZW-NOTKtsdD/U-DQ(ZN)BH LSOH single-mode 8J Eca (8 fibres G.652D) 2.0 kN

Code: L77008
€0.54
Price Disc. Quantity Validity
€0.54 0 % from 1 piece
Temporarily unavailable
The ZW-NOTKtsdD/U-DQ(ZN)BH 8J is a universal cable that can be used for indoor and outdoor connections.
• Fiber standard: G.652D
• Can be used indoors and outdoors
• LSZH sheath
• UV resistant
• Maximum tensile strength 2000 N
• Glass fibers to reinforce the cable and provide basic anti-rodent protection
• Ripcord for easy tearing of the outer sheath
• Very convenient to work with
• CPR class: Eca

Warranty

2-year warranty.

Support

Details

Note: the maximum cable length shipped in a parcel is 500 m. Longer sections can be shipped by courier.
Universal cable for indoor and outdoor applications ZW-NOTKtsdD/U-DQ(ZN)BH
8 single-mode fibers in G.652D
The ZW-NOTKtsdD/U-DQ(ZN)BH 8J is a universal cable that can be used for indoor and outdoor connections. The single-mode fibers are placed in a center tube filled with gel. The Gel filling the tube provides a protective layer for the fiber optics, cushioning the movement of the fibers when the cable moves and protecting the fibers from weathering. The glass fibers used in the cable structure are designed to protect the central tube with fiber optics from mechanical damage and rodents.
The cable sheath is made of LSOH / LSZH (flame retardant and non-toxic sheath) material. Increased class of reaction to fire: Eca.
Universal cables from the DRAKA series are gel-filled fiber optic cables intended for horizontal connections inside and outside buildings. Due to their small size and flexibility, the cables are ideal for installation in cable ducts. They are used in modern FTTH and FTTB systems, in server rooms, and between buildings. Unlike outdoor cables, universal cables can also be used inside buildings. This eliminates the need to create additional transitions, splices and cable distribution frames at the junction of the external and internal networks. Universal cables can be laid in cable ducts or even directly in trenches in the ground (in places where they are not exposed to direct mechanical damage).
Key features:
  • can be used indoors and outdoors
  • LSOH/LSZH sheath
  • UV resistant
  • maximum tensile strength 2000 N
  • central tube filled with gel
  • glass fibers to reinforce the cable and provide basic anti-rodent protection
  • ripcord for easy tearing of the outer sheath
  • very convenient to work with
  • CPR class: Eca
Complies with:
  • ISO/IEC 11801
  • PN-EN 50173
Cable structure:
1. Sheath
2. Glass fiber sheath
3. Plastic tube
4. Hydrophobic gel
5. Fibre




Customers can order any patch cords made to order with required terminating connectors. Please contact your sales assistant.
Price per 1m of the ZW-NOTKtsdD/U-DQ(ZN)BH 8J cable (8 fibres G.652D)
The table below shows possible coding variants
in accordance with the European standard DIN/VDE 0888:
Marking example
DIN/VDE 0888 cable designation
A A/I or U - universal cable
A - outdoor
I - indoor
D D - gel-filled tube
V - tight buffer tube
K - slotted core
W - twisted gel-filled loose tubes
Q Q - water resistive (fiber positioning or water swellable materials)
F - water resistive (core filling compound)
(ZN) Non-metallic reinforcement
B B - glass-fiber or aramid armoring against rodent attacks   SR - metallic armoring against rodent attacks
H H - halogen-free sheath
2Y - PE sheath
Y - PVC sheath
24 Number of fibers or number of tubes x number of fibers per tube
G G - multi-mode gradient fiber
E - single-mode fiber
9/125 Core diameter/sheath diameter
OS2 Category /Fiber standard

Specifications

Product type Fiber optic cable
Brand ALANTEC
Name U-DQ(ZN)BH
Cable type Universal
Number of fibers 8
Fibers type Single-mode, 9/125
standard G.652D
buffer 250 μm
Water penetration F5B method No penetration
CPR class Eca
Outer sheath material LSZH
Hydrophobic gel Yes
Gain Fiberglass
Central tube Yes
Outer diameter mm 5,5
Maximum pulling force dynamic N 2000
static N 1000
Min. bending radius static mm 60
installation mm 116
Temperature range operation °C -40...60
installation °C -5...70
storage °C -40...70
Cable length m Sold per meter